X19; X20 - LinMot E1450-PL-QN-0S Installation Manual

E14x0 v2 series
Hide thumbs Also See for E1450-PL-QN-0S:
Table of Contents

Advertisement

E1400 V2 Installation Guide

7.15 X19

X19
System
RJ-45
Use isolated USB-RS232 converter (Art.-No. 0150-2473 or 0150-3120) for configuration over RS232.

7.16 X20

X20
Analog In (+-10V Differential Analog Input)
RJ-45
7.17 S5
S5
Bus Termination / AnaIn2 Pull Down
S5
Page 16/27
1
Do not connect
2
Do not connect
3
RS232 Rx
4
GND
5
GND
6
RS232 Tx
7
Do not connect
8
Do not connect
case
Shield
1
Do not connect
2
Do not connect
3
Analog In -
4
GND
5
GND
6
Analog In +
7
Do not connect
8
Do not connect
case
Shield
Switch 6: Override Configuration Ethernet to DHCP
Switch 5: Bootstrap: Must be off for normal operation
Switch 4: CAN termination on ME (120R between pin 7 and 8 on X10/X11) on/off
Switch 3: CAN termination on CMD (120R between pin 7 and 8 on X7/X8) on/off
Switch 2: Termination resistor for RS485 on CMD (120R between pin 1 and 2 on X7/X8) on/off
Switch 1: AnIn2 pull down (4k7 Pull down on X4.4). Set to ON, if X4.4 is used as digital output.
Factory setting: all switches "on" except S5.5 (Bootstrap) and S5.6 (Override to DHCP)