Table 9-4 Menu 4 Regen parameter descriptions
Parameter
4.01

Current magnitude

4.02

Active current

4.04
Current demand
4.05
4.06
4.07
Symmetrical current limit
4.08
Reactive current reference
4.13
Current controller Kp gain
4.14
Current controller Ki gain
4.15
Thermal time constant
4.16
Thermal protection mode
4.17
Reactive current
4.18
Overriding current limit
4.19
Overload accumulator
4.20
Percentage load
4.24
User current maximum scaling
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
4.01
Current magnitude
Drive mode
Regen
Bit
SP
Coding
Range
Regen
Update rate
4ms
This parameter is the r.m.s. input current to the drive. The phase currents consist of an active component and a reactive component. The three phase
currents can be combined to form a resultant current vector as shown below:
y
Resultant
output current
Pr 4.02
Pr 4.01
Pr 4.17
x
The resultant current magnitude is displayed by this parameter. The active current is the torque producing current for a motor drive and the real
current for a Regen drive. The reactive current is the magnetising or flux producing current for a motor drive.
4.02
Active current
Drive mode
Regen
Bit
SP
Coding
Range
Regen
Update rate
4ms
The active current is the real current in a Regen drive.
Direction of active current
+
-
The active current is aligned with the y axis of the reference frame. The y axis of the reference frame is aligned with the Regen drive terminal voltage
vector.
102
System
Mechanical
design
installation
Range( )
0 to DRIVE_CURRENT_MAX A
±DRIVE_CURRENT_MAX A
±TORQUE_PROD_CURRENT_MAX %
0 to MOTOR1_CURRENT_LIMIT_MAX %
±REGEN_REACTIVE_MAX %
0 to 30,000
0 to 30,000
0.0 to 400.0
0 to 1
±DRIVE_CURRENT_MAX A
0 to TORQUE_PROD_CURRENT_MAX %
0 to 100.0 %
±USER_CURRENT_MAX %
0.0 to TORQUE_PROD_CURRENT_MAX %
Uni
Unipolar
Bi
NC
Not cloned
RA
FI
DE
Txt VM DP
ND
1
1
2
1
0 to DRIVE_CURRENT_MAX A
FI
DE
Txt VM DP
ND
1
1
2
1
±DRIVE_CURRENT_MAX A
Power flow
From supply
Into supply
www.controltechniques.com
Electrical
Getting
Optimisation
installation
started
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
Technical
Component
Parameters
data
sizing
Default( )
RO Uni FI NC PT
RO
Bi
RO Uni FI NC PT
175.0
RW Uni
0.0
RW Bi
90
RW Uni
2,000
RW Uni
89.0
RW Uni
0
RW Uni
RO
Bi
RO Uni
RO Uni
RO
Bi
175.0
RW Uni
Txt
Text string
US
User save
PS
PS
1
PS
Unidrive SP Regen Installation Guide
Diagnostics
Type
FI NC PT
US
US
US
US
US
FI NC PT
NC PT
NC PT
FI NC PT
US
Power down save
Issue Number: 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents