Single Regen, multiple motoring system using a Unidrive SPMC

Figure 4-2 Power connections: Single Regen, multiple motoring system
L1
L2
L3
F1
F2
F3
K1
VDR4
RFI
L1
Table 4-2 Key to Figure 4-3
Key
L1, L2, L3
Three phase supply
F1, F2, F3
Main regen system supply fuses
VDR1, VDR2, VDR3
Varistor network line-to-line
VDR4, VDR5, VDR6
Varistor network line-to-ground
F7, F8, F9, F10
DC bus fusing to motoring drive
F11, F12
DC bus fusing to Regen drive
F13, F14
SPMC DC fuse protection
RFI
Optional RFI filter
C1
Switching frequency filter capacitor
L1
Switching frequency filter inductor
L2
Regen inductor
K1
Main supply contactor
K2
Regen drive main contactor
K3
Charging contactor
OPD1
Overload protection device for C1
Aux.1
OPD NO auxiliary contact
Aux.2a
K2 NO auxiliary contact
Aux.2b
K2 NC auxiliary contact
Aux.2c
NC auxiliary for SPMC (optional)
Aux.3
K3 NC auxiliary contact
Rly.1
Optional isolation for enable between Regen and motoring drive(s)
Mt.1
Motor thermistor 1
Mt.2
Motor thermistor 2
Tc.1
Regen inductor thermistor
+DC, -DC
Motoring drive power connection to Regen drive
S1
Regen drive enable
S2
Motoring drive enable
S3
Motoring drive reset
S4
Motoring drive run forward
S5
Motoring drive run reverse
S6
Regen drive reset input (Pr 8.24 = Pr 10.33)
Vsupply
System control supply
34
System
Mechanical
design
installation
85
84
Unidrive
-DC
SPMC
+DC
L1 L2 L3
VDR3
VDR2
VDR6
Charging
L1
branch
circuit
AC Supply
Connections
Aux.3
K3
NOT USED
Regen drive
AC Supply
Connections
C1
U
K2
Aux.1
L2
Description
www.controltechniques.com
Electrical
Getting
Optimisation
installation
started
Aux.2c
+24Vdc external supply
0V common
F13
F14
F12
F11
-DC +DC
21
22
L2
L3
PE
Motoring
drive DC
Connections
V
W
1
2
3
4
5
2a 2b 2c
Aux
Figure 4-2 shows both the power and control connections for the
multiple motoring regen solution. For the multiple motoring system an
external charging circuit is required due to the additional capacitance
from the multiple motoring drives. The external charging circuit is
interlocked with the Regen drive enable to prevent operation with this
circuit still connected.
In this example, the external charging circuit consists of a Unidrive SPMC
module. Refer to section 3.5 Unidrive SPMC half controlled thyristor
rectifier on page 19 for further details of the Unidrive SPMC.
NOTE
For the multiple motoring drive solution, the Regen drive and associated
Unidrive SPMC must be sized to the total power requirements of all
motoring drives.
NOTE
The regen inductor duty is very arduous and therefore selection is critical.
As a result only regen inductors specified in this guide should be used.
NOTE
Fusing F4, F5, F6 are only required where fusing F1, F2, F3 exceed
these. For example in a multiple regen drive system, where F1, F2, F3
equal total system current rating.
NOTE
The SPMC uses the regen inductor as line reactors. The SPMC may be
powered from the incoming supply using a standard line reactor if
required.
Technical
Component
Parameters
data
Vsupply
Aux.2b
K3
Aux.2a
S6
23
24
25
26
27
28
29
30
6
7
8
9
10
11
41
Tc.1
Unidrive SP Regen Installation Guide
Diagnostics
sizing
-DC
+DC
S1
T.24
T.30
Rly.1
optional
31
42
K2
Vsupply
Issue Number: 2