Open Collector Output; T24 Digital I/O 1 Output Select; T28 & T29 Digital Input Auto-Selection Disable - Emerson SP1201 Installation Manual

Unidrive sp regen series 200v 400v 575v 690v
Table of Contents

Advertisement

Safety
Product
Introduction
Information
information
Pr 8.29 = 0 (negative logic)
Inputs
Non-relay Outputs
On (1) = <5V, OFF (0) = >15V
Relay outputs
OFF (0) = open, On (1) = closed
24V output (T22)
OFF (0) = 0V, On (1) = 24V
8.30

Open collector output

Drive mode
Regen
Bit
SP
Coding
1
Default
Regen
Update rate
Background
When this parameter is zero digital outputs are in push-pull mode. When this parameter is one either the high-side drive (negative logic polarity) or the
low-side driver (positive logic polarity) is disabled. This allows outputs to be connected in a wire-ORed configuration.
8.31

T24 digital I/O 1 output select

8.32
T25 digital I/O 2 output select
8.33
T26 digital I/O 3 output select
Drive mode
Regen
Bit
SP
Coding
1
Default
Regen
Update rate
Background
8.39
T28 & T29 digital input auto-selection disable
Drive mode
Regen
Bit
SP
Coding
1
Default
Regen
Update rate
Background
When this parameter is 0, Pr 8.25 and Pr 8.26 are set up automatically according to the setting of the reference select Pr 1.14. Setting this parameter
to 1 disables this function.
Reference select Pr 1.14
0, A1.A2
Reference selection by terminal input
1, A1.Pr
Analogue reference 1 or presets selected by terminal input
2, A2.Pr
Analogue reference 2 or presets selected by terminal input
3, Pr
Preset reference selected by terminal input
4, Pad
Keypad reference selected
5, Prc
Precision reference selected
NOTE
This parameter has no effect in Regen mode.
Unidrive SP Regen Installation Guide
Issue Number: 2
System
Mechanical
design
installation
<5V = 1, >15V = 0
OFF (0) = open, On (1) = closed
FI
DE
Txt VM DP
ND
OFF (0)
FI
DE
Txt VM DP
ND
Pr 8.31 and Pr 8.33 = On (1)
Pr 8.32 = OFF (0)
FI
DE
Txt VM DP
ND
OFF (0)
www.controltechniques.com
Electrical
Getting
Optimisation
installation
started
Pr 8.29 = 1 (positive logic)
<5V = 0, >15V = 1
OFF (0) = <5V, On (1) = >15V
OFF (0) = 0V, On (1) = 24V
RA NC NV
PT
US RW BU
1
RA NC NV
PT
US RW BU
1
RA NC NV
PT
US RW BU
1
Pr 8.25 set to:
Pr 1.41 - Analogue ref 2 select
Pr 1.45 - preset select bit 0
Pr 1.45 - preset select bit 0
Pr 1.45 - preset select bit 0
Pr 1.41 - Analogue ref 2 select
Pr 1.41 - Analogue ref 2 select
Technical
Component
Parameters
data
PS
1
PS
1
PS
1
Pr 8.26 set to:
Pr 6.31 - jog
Pr 1.46 - preset select bit 1
Pr 1.46 - preset select bit 1
Pr 1.46 - preset select bit 1
Pr 6.31 - jog
Pr 6.31 - jog
Diagnostics
sizing
137

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents