Connecting The Power Converter To A Dc Power Source - Cisco IE-4000-4TC4G-E Hardware Installation Manual

Ie-4000 series
Table of Contents

Advertisement

Connecting to Power
Replace the plastic cover over the terminal block.
Step 6
Connect the other end of the wiring to your AC power source.
Step 7

Connecting the Power Converter to a DC Power Source

You can also connect the power converter to a DC power source. Several power supplies can be used.
Refer to
Use copper conductors only, rated at a minimum temperature of 167°F (75°C).
Note
Measure a single length of stranded copper wire long enough to connect the power converter to the earth
Step 1
ground. The wire color might differ depending on the country that you are using it in.
For connections from the power converter to earth ground, use shielded 14-AWG stranded copper wire.
Measure a length of twisted-pair copper wire long enough to connect the power converter to the DC
Step 2
power source.
For DC connections from the power converter to the DC source, use 10-AWG twisted-pair copper wire.
Using a 18-gauge wire-stripping tool, strip the ground wire and both ends of the twisted pair wires to
Step 3
0.25 inch (6.3 mm) ± 0.02 inch (0.5 mm). Do not strip more than 0.27 inch (6.8 mm) of insulation from
the wires. Stripping more than the recommended amount of wire can leave exposed wire from the power
and relay connector after installation.
Connect one end of the stranded copper wire to a grounded bare metal surface, such as a ground bus, a
Step 4
grounded DIN rail, or a grounded bare rack.
Insert the other end of the exposed ground wire lead into the earth-ground wire connection on the power
Step 5
converter terminal block. Only wire with insulation should extend from the connection. See
item 1. Note that the position of the power converter may vary on different switch models.
Tighten the earth-ground wire connection terminal block screw.
Step 6
Torque to 8 in.-lb, not to exceed 10 in-lb.
Note
An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be
Warning
sure that no exposed portion of the DC-input power source wire extends from the power and relay
connector. Statement 122
Insert the twisted-pair wire leads into the terminal block line and neutral connections. Insert the wire
Step 7
(labeled number 1 in
in
Figure
connectors. See
Tighten the line and neutral terminal block screws.
Step 8
Torque to 8 in.-lb, not to exceed 10 in-lb.
Note
Cisco IE 4000 Switch Hardware Installation Guide
2-12
Table 2-1 on page 2-8
for the appropriate DC input ratings.
Figure
2-3) lead into the neutral wire connection and the wire (labeled number 2
2-3) lead into the line wire connection. Ensure that only wire with insulation extends from the
Figure
2-3.
Chapter 2
Switch Installation
Figure
2-3,

Hide quick links: