ACME LED-BL4B User Manual

Stage blinder b4

Advertisement

Quick Links

Stage Blinder B4
LED-BL4B
User Manual
Please read the user manual before use

Advertisement

Table of Contents
loading

Summary of Contents for ACME LED-BL4B

  • Page 1 Stage Blinder B4 LED-BL4B User Manual Please read the user manual before use...
  • Page 2: Table Of Contents

    Contents 1. Safety Instructions……………………………………………………….2 2. Technical Specifications…………………………………………………5 3. Installation…………………………………………………………………6 4. How to set the unit………………………………………………….…….6 4.1 Rear Panel…………………………………………………………………6 4.2 Main Function…………………………………………………………….8...
  • Page 3: Safety Instructions

    5. How To Control The Unit………………………………………………..12 6. DMX Channel Mode……………………………………………………….13 7. DMX512 Connections…………………………………………………..15 8. Troubleshooting……………………………………………………………16 9. Fixture Cleaning…………………………………………………………….17 1. Safety Instructions Please read the instructions carefully which includes important information about the installation, operation and maintenance. WARNING  Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet.
  • Page 4  Please unpack and check carefully there is no transportation damage before using the fixture.  Please disconnect main power before servicing and maintenance.  The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces.
  • Page 5: Technical Specifications

    For AC 220-240V power supply, the maximum fixtures that can be connected on one power cable is 4(including the first fixture) ; For AC 100~120V power supply, the maximum fixtures that can be connected on one power cable is 2 (including the first fixture). 2.
  • Page 6: Installation

    3. Installation The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight.
  • Page 7 ○ 1 Mains input/output: Connect to supply mains power, and connect to supply mains power for the next unit. ○ 2 Fuse holder: T6.3A ○ 3 CA-8 Connector: Connect with easy controller CA-8 ○ 4 Sound Active Port: Receive Sound active signal ○...
  • Page 8: Main Function

    Slave Slave Sound Flash Sound active signal input ○ 8 Display: Show the various menus and the selected functions 4.2 Main Function To select any functions, press MENU button until the required one is shown on the display. Select the function by ENTER button. Use DOWN and UP button to change the mode. Once the required mode has been selected, press ENTER button to setup or it will return to the main functions without any change after idling 8 seconds automatically.
  • Page 9 automatically. Back to the previous functions without any change press the MENU button. Channel Mode Select the , press the ENTER button. Use the DOWN and UP button to select the channel mode (1/ 2/4/5CH)( 1 channel mode control bright of 4 LED, 2 channel mode means 1st channel mode control bright of 4 LED , 2 channel control effect of 4 LED, 4 channel mode control bright of 4 LED by separate, 5 channel mode control bright of 4 LED by...
  • Page 10 again). Once selected, press the ENTER button to setup or exit menu mode without any change after 8 seconds automatically. Back to the functions without any change press the MENU button again. Display direction Select the , press the ENTER button. Use the DOWN and UP button to select (positive display) or (reverse display).
  • Page 11: How To Control The Unit

    5. How To Control The Unit 5.1 Two ways to operate the unit: 1. By master/slave 2. By DMX controller No need to turn the unit off when you change the DMX address, as new DMX address setting will be affected at once. Turn on the unit, under the DMX signal , the LED will display the saved channel address(001-512);...
  • Page 12 Channel mode:...
  • Page 13: Dmx512 Connections

    7. DMX512 Connections Mode connection: 1. Connect the fixture together in a “daisy chain” by XLR plug cable from the output of the fixture to the input of the next fixture. The cable cannot be branched or split to a “Y” cable.
  • Page 14: Troubleshooting

    when one of the units’ power is disconnected. 3. At last fixture, the DMX cable has to be terminated with a terminator to reduce signal errors. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture. 4.
  • Page 15: Declaration Of Conformity

    frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture’s optics.  Clean with soft cloth using normal glass cleaning fluid.  Always dry the parts carefully. ...
  • Page 17 Innovation, Quality, Performance...

Table of Contents