Verifying Status Monitor Configuration Locally - Cisco GS7000 Installation And Operation Manual

Gainmaker node seg2way status monitor/local control module
Table of Contents

Advertisement

9
On the toolbar, click the Save to Database button.
10 On the toolbar, click the Download Config to Resource button.
Note: This step could take about a minute or two depending on the total number
of devices that are currently deployed and being monitored.
Result: When completed a detailed description is displayed in the Activity Log
window.
11 Close the Configuration Wizard and return to the CheetahNet System Manager.
12 On the System Manager menu bar, select Request - Load Network Elements -
All Newly Added Devices.
Result: The new device should now display in the System Manager tree view
under the associated HEC RF modem.

Verifying Status Monitor Configuration Locally

In the event that communications with the SM/LCM in CheetahNet is not successful
it is recommended that the specific communication parameters be verified via a local
connection to the device. The following equipment is required:
The Test2Way™ for Scientific Atlanta GS7000 Seg2Way SM/LCM application
A Scientific Atlanta local interface cable (part number 1004044)
A Windows-based laptop computer with a DB-9 serial port connector
Note: If the device has already been added to the CheetahNet system you should
place the device in maintenance mode (polling off) before connecting to it locally.
Connect as shown in the following illustration and start the Test2Way for Scientific
Atlanta GS7000 Seg2Way SM/LCM application.
4022871 Rev C