3
Tighten the module hold-down screws to secure the module in the lid. Torque
the screws from 25 to 30 in-lbs (2.8 to 3.4 Nm).

Closing the Housing

Close the housing as follows.
1
Ensure any worn gaskets are replaced, and the gaskets are clean and in the
correct position.
2
Carefully close the lid.
3
For strand-mounted housings, pull the lid away from the base and remove the
slack from the hinge before rotating the lid up toward the base.
4
Ensure no cables are pinched between lid and base.
5
Secure lid to base with bolts. Tighten from 5 to 12 ft-lbs (6.8 to 16.3 Nm) in the
sequence shown in the following illustration. Repeat the sequence twice, ending
with the final torque specification.
4022871 Rev C
CAUTION:
Use caution when closing housing. Improper closing may result in the Model
GS7000 Node not being sealed from the environment.
Installing the SM/LCM
15