Cisco GS7000 Installation And Operation Manual page 33

Gainmaker node seg2way status monitor/local control module
Table of Contents

Advertisement

Menu Item Configuration Parameter
1
2
3
4
4022871 Rev C
RX & TX Config
RX1
RX2
RX3
RX4
TX1
TX2
TX3
TX4
PS Config
AC1
AC2
PS1
PS2
RX Tresholds
RX1 Min
RX2 Min
RX3 Min
RX4 Min
RX1 Max
RX2 Max
RX3 Max
RX4 Max
TX Thresholds
TX1 Min
TX2 Min
TX3 Min
TX4 Min
TX1 Max
TX2 Max
TX3 Max
TX4 Max
Local Control Module Configuration Procedure
Description/Values
Description: Read/Write configurable
parameter. Specifies whether receivers 1
through 4 and transmitters 1 through 4 are
installed in the node.
Values: Present, Absent
Description: Read/Write configuration
parameter. Specifies whether AC input power 1
and/or 2, and power supplies 1 and 2 are
installed in the node.
Values: Present, Absent
Description: Read/Write configuration
parameter. Specifies the switching levels for the
two AB switches. Enter minimum and
maximum power thresholds for receivers 1
through 4 switching levels.
Values: #.# mW
Defaults: 0.5 mW min., 2.0 mW max.
Description: Read/Write configuration
parameter. Specifies the minimum and
maximum power thresholds for transmitters 1
through 4 switching levels.
Values: #.# mW
Defaults: 0.5 mW min., 2.3 mW max.
19

Advertisement

Table of Contents
loading

Table of Contents