UMSITRAPDS3-1
TABLE 9-10 Models 7MF4633 and 7MF4812, Model Designation
Flanged level transmitter, two-wire, series DSIII, 7MF4633-
Measuring cell filling
Silicone oil
Span
25 to 250 mbar
25 to 600 mbar
53 to 1600 mbar
0.16 to 5 bar
Process connection of low pressure side
Female thread 1/4-18 NPT with flange connection
Mounting thread M10 to DIN 19213
•
Mounting thread 7/16-20 UNF to EN 61518
•
Non-wetted parts materials
Process flange screws
Stainless steel
Stainless steel
Version
Standard version
•
International version, English label inscription and documentation in 5 languages on CD
•
Explosion protection
Without
•
With ATEX, type of protection:
•
- Intrinsic safety (EEx ia)
- Explosion proof (EEx d)
- Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)
- Ex nA/nL (Zone 2)
- Intrinsic safety, explosion-proof enclosure, and dust explosion protection (EEx ia +
EEx d + Zone 1D/2D)
•
With FM + CSA, type of protection: intrinsic safety and explosion proof (is +xp)
Electrical connection / Cable Entry
Screwed gland PG 13.5; Adapter
•
•
Screwed gland M20 x 1.5
Screwed gland 1/2-14 NPT
•
Han 7D plug (plastic housing ) includes mating connector
•
M12 connectors (metal)
•
Display
Without (digital indicator hidden, setting: mA)
•
With visible digital indicator
•
With customer specific digital indicator and setting, order code Y21 or Y22 required
•
Additional selections and data on next two pages.
November 2010
Measuring cell cleaning
Standard
(0.36 to 3.63 psi)
(0.36 to 8.70 psi)
(0.8 to 23.2 psi)
(2.3 to 72.5 psi)
Electronics housing
Die-cast aluminum
Fine precision stainless steel
Model Designations and Specifications
Y
-
1
D
E
F
G
0
2
2
3
1
2
A
B
D
P
E
R
N C
A
B
C
D
F
1
6
7
9-25