4.0 INSTALLATION

Transmitter installation is discussed in this section. Topics include: equipment delivery and handling,
environmental and installation considerations, and mechanical and electrical installation.
Read the information on the transmitter's rating and approval plates and ensure that the correct model
is at hand and that the correct procedures in this manual are followed. See Section 9.1 Model
Designations for an explanation of the model designation alphanumeric sequence shown on the rating
plate.
The installation must conform to the National Electrical Code and all other applicable construction
and electrical codes. Refer to the installation drawings in Appendix B when locating a transmitter in a
hazardous area.
Refer to Section 9.6 Hazardous Area Classifications for approval agency requirements that affect
installation and use of the instrument and for additional statements concerning installation in a
hazardous environment.

4.1 EQUIPMENT DELIVERY AND HANDLING

Prior to shipment, a transmitter is fully tested and inspected to ensure proper operation. It is then
packaged for shipment. Most accessories are shipped separately. The contents of a box are listed on a
packing slip.

4.1.1 Receipt of Shipment

Each carton should be inspected at the time of delivery for possible external damage. Any visible damage
should be recorded immediately on the carrier's copy of the delivery slip.
Each carton should be unpacked carefully and its contents checked against the enclosed packing list. At
the same time, each item should be inspected for any hidden damage that may or may not have been
accompanied by exterior carton damage.
If it is found that some items have been damaged or are missing, notify Siemens immediately and provide
full details. In addition, damage must be reported to the carrier with a request for their on-site inspection
of the damaged item and its shipping carton.

4.1.2 Storage

If a transmitter is to be stored for a period prior to installation, review the environmental requirements in