  • Page 1 Radar Transmitters SITRANS Probe LU (PROFIBUS PA) Quick Start Manual 12/2013 SITRANS...
  • Page 3: Safety Guidelines

    SITRANS Probe LU (PROFIBUS PA) Quick Start Manual This manual outlines the essential features and functions of the SITRANS Probe LU (PROFIBUS PA). We strongly advise you to acquire the detailed version of the manual so you can use your instrument to its fullest potential.
  • Page 4 The transducer is available in ETFE (ethylene-tetrafluoroethylene) or PVDF (polyvinylidene fluoride), allowing SITRANS Probe LU to be used in a wide variety of industries and applications using corrosive chemicals. The ultrasonic transducer contains a temperature-sensing element to compensate for temperature changes in the application.
  • Page 5: Specifications

    Specifications For a complete listing, see the SITRANS Probe LU (PROFIBUS PA) Operating Instructions. For Approvals information, please refer to the device nameplate Ambient/Operating Temperature Note: Process temperature and pressure capabilities are dependent upon information on the device nameplate. The reference drawing listed on the nameplate can be downloaded from the Siemens website.
  • Page 6: Installation

    Installation shall only be performed by qualified personnel and in accordance with local governing regulations. • SITRANS Probe LU is to be used only in the manner outlined in this manual, otherwise protection provided by the equipment may be impaired. Note: Please refer to the device nameplate for approval information.
  • Page 7: Mounting Instructions

    300 mm (1 ft) above the highest anticipated level. SITRANS Probe LU is available in three thread types: 2" NPT, 2" BSP , or PF2/G (BS EN ISO 228-1). Before inserting SITRANS Probe LU into its mounting connection, ensure that the threads are of the same type to avoid damaging them.
  • Page 8 2.092), available from www.profibus.com. If cable is routed through conduit, use only approved suitable-size hubs for waterproof applications. The instrument shield connection is internally connected to the external ground lug. Page EN-6 SITRANS Probe LU (PROFIBUS PA) – QUICK START MANUAL A5E32081626...
  • Page 9: Wiring Setups For Hazardous Area Installations

    Assembled in Canada with domestic and imported parts FM/CSA Intrinsically Safe connection drawing number 23650617 can be downloaded from the product page of our website at: www.siemens.com/probelu. Go to Support > Installation Drawings > Level Measurement > Continuous - Ultrasonic.
  • Page 10: Instructions Specific To Hazardous Area Installations (Reference European Atex Directive 94/9/Ec, Annex Ii, 1/0/6)

    This shall be considered when the SITRANS Probe LU (PROFIBUS PA) is being installed in locations that specifically require group II, category 1G equipment.
  • Page 11: Communications Via Profibus Pa

    Configuring the PROFIBUS PA master To configure SITRANS Probe LU on the network, you will need the GSD file. You can download the files (SIEM8124.gsd for the 6 m Probe LU, or SIEM8123.gsd for the 12 m Probe LU) from our web site.
  • Page 12: Normal Operation

    PDM and PROFIBUS PA. (For charts showing the complete menu structure, refer to the full manual.) For more details on Loss of Echo, refer to the full manual. Page EN-10 SITRANS Probe LU (PROFIBUS PA) – QUICK START MANUAL A5E32081626...
  • Page 13: The Handheld Programmer

    • In Edit mode, the PROGRAM icon appears and flashes. PROGRAM Mode Display SITRANS Probe LU (PROFIBUS PA) continues to monitor In and Out values even when Note: the device is in PROGRAM mode. 1 – Primary region (displays parameter value) 2 –...
  • Page 14: Write Locking

    • To enable programming, set REMLOCK to 0. To disable programming, enter 1. Master Reset In PDM, open the menu Device – Master Reset, to access the reset options, including Factory Reset. Page EN-12 SITRANS Probe LU (PROFIBUS PA) – QUICK START MANUAL A5E32081626...
  • Page 15: Activating Sitrans Probe Lu

    Keep infrared devices such as laptops, cell phones, and PDAs, away from SITRANS Note: Probe LU (PROFIBUS PA) to prevent inadvertent operation. Power up the instrument. SITRANS Probe LU (PROFIBUS PA) starts in RUN mode, and the LCD displays the output of AIFB1. Network Address (default 126)
  • Page 16: Changing Parameter Settings

    Changing parameter settings • First launch SIMATIC PDM, connect to SITRANS Probe LU (PROFIBUS PA), and upload data from the device. • Adjust parameter values in the parameter view field (right side of screen). • After adjusting the value, press Enter (the status fields read Changed).
  • Page 17: Auto False Echo Suppression

    Distance (meters) Display after Auto False Echo Suppression TVT curve material (learned) level false echo Distance (meters) This parameter cannot be reset to the factory default. A5E32081626 SITRANS Probe LU (PROFIBUS PA) – QUICK START MANUAL Page EN-15...
  • Page 18: Maintenance

    Unit Repair and Excluded Liability For detailed information, please see the inside back cover. Temperature dependent: typical value at +20 °C (+68 °F); maximum value at +80 °C (+176 °F). Page EN-16 SITRANS Probe LU (PROFIBUS PA) – QUICK START MANUAL A5E32081626...
  • Page 19: Appendix A: Connection Drawings

    18 / APRIL / 2005 R. CLYSDALE SITRANS Probe LU E. DeSIMONE PROFIBUS PA S. NGUYEN CONNECTION DRAWING PETERBOROUGH FOR INTERNAL USE ONLY 23650617 2365061701 1 : 1 A5E32081626 SITRANS Probe LU (PROFIBUS PA) – QUICK START MANUAL Page A-1...
  • Page 20 18 / APRIL / 2005 R. CLYSDALE SITRANS Probe LU E. DeSIMONE PROFIBUS PA S. NGUYEN CONNECTION DRAWING PETERBOROUGH FOR INTERNAL USE ONLY 23650617 2365061701 1 : 1 Page A-2 SITRANS Probe LU (PROFIBUS PA) – QUICK START MANUAL A5E32081626...
  • Page 21 18 / APRIL / 2005 R. CLYSDALE SITRANS Probe LU E. DeSIMONE PROFIBUS PA S. NGUYEN CONNECTION DRAWING PETERBOROUGH FOR INTERNAL USE ONLY 23650617 2365061701 1 : 1 A5E32081626 SITRANS Probe LU (PROFIBUS PA) – QUICK START MANUAL Page A-3...
  • Page 22 18 / APRIL / 2005 R. CLYSDALE SITRANS Probe LU E. DeSIMONE PROFIBUS PA S. NGUYEN CONNECTION DRAWING PETERBOROUGH FOR INTERNAL USE ONLY 23650617 2365061701 1 : 1 Page A-4 SITRANS Probe LU (PROFIBUS PA) – QUICK START MANUAL A5E32081626...
  • Page 23 29 / SEPT / 2004 R. CLYSDALE SITRANS Probe LU S. MILLIGAN CLASS I, Div. 2 S. NGUYEN CONNECTION DRAWING PETERBOROUGH FOR INTERNAL USE ONLY 23650583 2365058300 1 : 1 A5E32081626 SITRANS Probe LU (PROFIBUS PA) – QUICK START MANUAL Page A-5...
  • Page 24 For more information www.siemens.com/level www.siemens.com/weighing Siemens AG Subject to change without prior notice Industry Sector A5E32081626 Rev. AB 1954 Technology Drive P.O. Box 4225 *A5E32081626* © Siemens AG 2013 Peterborough, ON Canada K9J 7B1 Printed in Canada email: techpubs.smpi@siemens.com www.siemens.com/processautomation...