UMSITRPDS3-1
Calibration Procedure Section References
Calibration Needed
Position-induced zero
On-line zero
Calibrate DAC
This completes calibration of the transmitter.

7.2 PREVENTIVE MAINTENANCE

Preventive maintenance consists of periodic inspection of the transmitter, cleaning the external surface of
the transmitter enclosure, draining condensate from conduit, and blowing-down or purging impulse
piping to keep them free of sediment. Perform preventive maintenance at regularly scheduled intervals.

7.2.1 Transmitter Exterior Inspection

The frequency of the inspection will depend on the severity of the transmitter's environment.
1. Inspect the exterior of the transmitter enclosure for accumulated oil, dust, dirt, and especially any
corrosive process over-spray.
2. Check that both enclosure caps are fully threaded onto the enclosure, compressing the O-ring between
the cap and the enclosure. The O-ring must not be cracked, broken, or otherwise damaged.
3. Inspect the display viewing glass for cleanliness and damage. Replace the enclosure cap assembly if
the glass is damaged or missing.
4. Inspect both enclosure electrical conduit entrances for possible moisture leaks. An unused conduit
entrance must be plugged and sealed. Inspect the cable clamps of all watertight cable conduits for
loose clamps and deteriorated sealing material. Tighten clamps and reseal as necessary.
5. Inspect conduit drain seals for obstructions.
6. Inspect transmitter and mounting bracket hardware for tightness. Tighten loose hardware as
necessary. Consider steps to reduce vibration.
7. Inspect process connection blocks for evidence of leakage at the impulse pipe connections and at the
block interface to the transmitter end caps. As necessary, add sealant to pipe threads, tighten block
bolts, and replace block Teflon® seals.

7.2.2 Transmitter Exterior Cleaning

After an exterior inspection of the transmitter, the enclosure can be cleaned with the transmitter operating.
1. Clean the enclosure (except enclosure cap glass) and process manifold with a mild, nonabrasive liquid
detergent, and a soft bristle brush, sponge, or cloth. Rinse the weatherproof enclosure with a gentle
spray of water.
Remove an excessive accumulation of process residue. Hot water or air may be used to flush away process
residue if the temperature of the cleaning medium does not exceed the operating temperatures of the transmitter
as listed in Section 9.3 Specifications.
2. Clean enclosure cap glass with a mild, nonabrasive liquid cleaner and a soft, lint-free cloth.
November 2010
Local (Pushbutton)
Section 6.2.5
Section 6.2.2
---
Calibration And Maintenance
HART Communicator
Section 6.4.4
Section 6.4.2
Section 6.4.14
7-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7mf40337mf42337mf44337mf45337mf46337mf4812

Table of Contents