5 Config inp/outp,
3 Output
Continued
4 Local meter
5 Mech. Construction
Mech = mechanical
6 Diagnosis/Service
1 Status
2 Device
Continued on pg 4
Online Configuration Map for
Siemens SITRANS P DSIII Pressure Transmitter with
Model 375 Field Communicator
1 Analog output
1 Analog output +
2 Percent range +
3 Pres xfer function
NA/4 Startpoint square root
4/5 Zero and Span
5/6 Current Limits
6/7 Alarms / Failsafe
2 Sensor trim points
1 Lower sensor trim point
2 Upper sensor trim point
3 HART output
1 Polling address
2 Num request preambles
3 Num response preambles
1 Meter type
2 Unit tracking
3 Local Display unit
4 LCD Settings
1 LCD Scaling, if On:
5 Bargraph
6 Access Control
1 Local keys control mode
2 Write protect
3 Set write protect --> M
1 No of electronic changes
2 Design
1 Sensor
2 Remote Seal
3 Process Connection
1 Process Connection
2 DrainVent / plug mat
3 DrainVent / plug pos
4 Process flange bolt
5 Flange type
6 Flange material
4 Electronic Connection
1 Electr housing material
2 Electr connection
1 Status summary
2 Extended device status
3 Hardw/Firmw status
1 RAM failure
2 ROM failure
3 Electronic EEPROM
# List continues
4 Diag Alarm Status
1 Calibration Alarm
2 Service Alarm
# List continues
5 Diag Warn Status
1 Calibration Warning
2 Service warning
# List continues
6 Simulation status
1 Pressure simulation
2 El simulation
3 Sensor temp simulation
1 Selftest/Reset
1 Selftest --> M
2 Display Test --> M
3 Master reset --> M
4 Changes Config
2 Sensor trim
1 Restore mfgr trims --> M
2 Sensor trim
3 Trim analog output
4 Position correction
3 Simulation/Test
1 Loop test --> M
2 Inputs --> M
4 Access Control
1 Local keys control mode
2 Write protect
3 Set write protect --> M
Page 3
Linear
Sq Rt, lin to Strtpt
Sq Rt, 4 mA to Strtpt
Sq Rt, 2 steps lin to Startpt
1 Zero/Span set
1 Out Scaling PV >1
2 Apply values >2
1 Lower AO Limit
2 Upper AO Limit
1 AO Alarm / FS Type (Hi/Lo)
2 Alarm / FS LRV
3 Alarm / FS URV
2 LCD Unit
3 LCD LRV
4 LCD URV
1 Fill fluid
2 Isolation material (diaphr)
3 O ring material
4 Module range
1 Number remote seal (RS)
2 RS type
3 RS isolator material
4 RS fill fluid
5 Extension length
6 Extension type
7 Capillary length
OFF = OK
ON = Problem
1 Config changed counter
mfgr = manufacturer
1 Sensor trim points
1 Lower sensor trim point
2 Upper sensor trim point
2 Sensor trim
1 Pres zero trim--> M
2 Lower sensor trim --> M
3 Upper sensor trim --> M
3 Trimpoint summary
1 D/A trim --> M
2 Scaled D/A trim --> M
1 Position corr --> M
Simulation AO
Simulation Fixed / Ramp