Preventive Maintenance - WEG CFW300 User Manual

Hide thumbs Also See for CFW300:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting and Maintenance

6.4 PREVENTIVE MAINTENANCE

DANGER!
Always turn off the mains power supply before touching any electrical component
associated to the inverter.
High voltages may still be present even after disconnecting the power supply.
To prevent electric shock, wait at least ten minutes after turning off the input
power for the complete discharge of the power capacitors. Always connect the
equipment frame size to the protective ground (PE). Use the adequate connection
terminal at the inverter.
ATTENTION!
The electronic boards have electrostatic discharge sensitive components.
Do not touch the components or connectors directly. If necessary, first touch the
grounded metallic frame size or wear a ground strap.
Do not perform any withstand voltage test: if necessary, consult WEG.
The inverters require low maintenance when properly installed and operated.
28
presents the main procedures and time intervals for preventive maintenance.
on page 29
provides recommended periodic inspections to be performed every 6 months
after the inverter start-up.
Maintenance
Fan replacement
Electrolytic
If the inverter
capacitors
is stocked (not
being used):
"Reforming"
Inverter is being
used: replace
28 | CFW300
Table 6.2: Preventive maintenance
Interval
After 40000 operating hours
Every year from the
manufacturing date printed on
the inverter identification label
(refer to
Section 2.5 RECEIVING
AND STORAGE on page
8).
Every 10 years
Table 6.2 on page
Instructions
Replacement
Apply power to the inverter (voltage between
220 and 230 Vac, single-phase/three-phase or
DC (according to the model of the inverter), 50 or
60 Hz) for at least one hour. Then, disconnect
the power supply and wait at least 24 hours
before using the inverter (reapply power)
Contact WEG technical support to obtain
replacement procedures
Table 6.3