KC9111/KC9111-2 & KC9321/KC9321-2 INSTALLATION
12) Partially Tighten the Set Screw:
Using a 1/16" Allen wrench, partially turn
in the set screw until outer end of set
screw is about flush with surface of base-
plate.
13) Fully Tighten the Set Screw:
Finish turning in the set screw until it hits the stop.
IMPORTANT: At this time, outer end of set screw should
be a little bit below the surface of the baseplate, as shown in
photo A. If you have turned in set screw as far as it will go
and it is protruding beyond the surface of baseplate, as
shown in photo B, the most probable cause is that dead
latch was not positioned properly (see Position the Dead
Latch's Set Screw Hole: on page 10).
If you have turned the set screw in as far as it will go and it is
protruding from the surface of the baseplate, do the following:
Turn set screw back out so that about 1/4" is pro-
truding from surface of baseplate.
Reposition critical edge on dead latch according to
the instructions on page 10).
Turn set screw in until it just hits the stop.
IMPORTANT: Do not overtighten set screw because the
baseplate may start to bow outward resulting in a gap
between trim and door when trim is mounted.