5-6 Setting/Releasing the Forced-zero
Operation
Setting the forced-zero
The forced-zero operation is
not
available
when
the
current value is not normal
(input abnormally, outside-
the-range
specified,
not
measured yet).
Releasing the forced zero

5-6 Setting/Releasing the Forced-zero Operation (K3MA-J)

(K3MA-J)
The forced-zero operation allows you to shift the current value to zero forcedly.
Procedure
A.
Press the U key when a current value is displayed on the main indicator.
(Release the key within one second.)
The current value will be shifted to zero.
"ZERO" in the operator indication section is illuminated, indicating the cur-
rent value has been shifted to zero.
Release the forced-zero operation.
Procedure
A.
Press the U key and hold it down for at least one second when a shifted value
is displayed.
The shifted value will be restored to the current value.
"ZERO" in the operation indicator section will go off, indicating the current
value is no longer shifted.
Operation level
5-9