Omron K3MA-J User Manual page 104

K3ma series, digital panel meters, process/temperature/frequency/rate meter
Hide thumbs Also See for K3MA-J:
Table of Contents

Advertisement

APPENDIX
Input Characteristics
K3MA-J
Input type
Setting range
0-20
0 to 20mA
4-20
4 to 20mA
0-5
0 to 5V
1-5
1 to 5V
5
±5V
10
±10V
K3MA-L
Input type
Pt100
Platinum resistance
thermometer
JPt100
K
J
T
E
Thermocouple
L
U
N
R
S
B
K3MA-F
Pulse frequency
30
0.05 to 30Hz (Minimum pulse width: 15ms)
5k
0.05 to 5kHz (Minimum pulse width: 90μs)
A-4
Control range
-2 to 22mA
2 to 22mA
±0.1%FS±1digit max. at 23°C±3°C
-0.5 to 5,5V
0.5 to 5.5V
±5.5V
±0.1%FS±1digit max. at 23°C±5°C
±11V
Set
Setting range
Control range
value
-200 to 850°C
-220 to 870°C
0
-300 to 1500°F
-340 to 1540°F
-199.9 to 500.0°C
-199.9 to 520.0°C
1
-199.9 to 900.0°F
-199.9 to 940.0°F
0.0 to 100.0°C
-20.0 to 120.0°C
2
0.0 to 210.0°F
-40.0 to 250.0°F
-199.9 to 500.0°C
-199.9 to 520.0°C
3
-199.9 to 900.0°F
-199.9 to 940.0°F
0.0 to 100.0°C
-20.0 to 120.0°C
4
0.0 to 210.0°F
-40.0 to 250.0°F
-200 to 1300°C
-220 to 1320°C
5
-300 to 2300°F
-340 to 2340°F
-20.0 to 500.0°C
-40.0 to 520.0°C
6
0.0 to 900.0°F
-40.0 to 940.0°F
-100 to 850°C
-120 to 870°C
7
-100 to 1500°F
-140 to 1540°F
-20.0 to 400.0°C
-40.0 to 420.0°C
8
0.0 to 750.0°F
-40.0 to 790.0°F
-200 to 400°C
-220 to 420°C
9
-300 to 700°F
-340 to 740°F
-199.9 to 400.0°C
-199.9 to 420.0°C
10
-199.9 to 700.0°F
-199.9 to 740.0°F
0 to 600°C
-20 to 620°C
11
0 to 1100°F
-40 to 1140°F
-100 to 850°C
-120 to 870°C
12
-100 to 1500°F
-140 to 1540°F
-200 to 400°C
-220 to 420°C
13
-300 to 700°F
-340 to 740°F
-199.9 to 400.0°C
-199.9 to 420.0°C
14
-199.9 to 700.0°F
-199.9 to 740.0°F
-200 to 1300°C
-220 to 1320°C
15
-300 to 2300°F
-340 to 2340°F
0 to 1700°C
-20 to 1720°C
16
0 to 3000°F
-40 to 3040°F
0 to 1700°C
-20 to 1720°C
17
0 to 3000°F
-40 to 3040°F
100 to 1800°C
0 to 1820°C
18
300 to 3200°F
0 to 3240°F
Setting range
Measuring accuracy
Indication accuracy
±0.5% of indicated value or ±1°C, whichever is larger
±1digit max.
±0.5% of indicated value or ±1°C, whichever is larger
±1digit max.
(at a temperature of -100°C or less: ±2°C±1digit max.)
±0.5% of indicated value or ±1°C, whichever is larger
±1digit max.
±0.5% of indicated value or ±1°C, whichever is larger
±1digit max.
(at a temperature of -100°C or less: ±2°C±1digit max.)
±0.5% of indicated value or ±1°C, whichever is larger
±1digit max.
±2°C±1digit max.
±0.5% of indicated value or ±1°C, whichever is larger
±1digit max.
(at a temperature of -100°C or less: ±2°C±1digit max.)
±0.5% of indicated value or ±1°C, whichever is larger
±1digit max.
(at a temperature of 200°C or less: ±3°C±1digit max.)
±0.5% of indicated value or ±1°C, whichever is larger
±1digit max.
(at a temperature of 400°C or less is unrestricted.)
Measuring accuracy
±0.1%FS±1digit max. at 23°C±5°C

Advertisement

Table of Contents
loading

This manual is also suitable for:

K3ma-lK3ma-f

Table of Contents