Omron K3MA-J User Manual page 66

K3ma series, digital panel meters, process/temperature/frequency/rate meter
Hide thumbs Also See for K3MA-J:
Table of Contents

Advertisement

CHAPTER 5 OPERATION
Teaching scaling
5-20
E.
Use the S and U key to change the set value.
F.
Press the M key to go to the next parameter.
• The change in setting is saved and "dsp" will
appear on the main indicator.
G.
Repeat the operations of
parameter "dsp"
• When the parameter "dsp" has been set, the next
parameter "dp" will appear on the main indica-
tor.
H.
Press the L key and hold it down for at least
one second to return to the operation level.
The teaching function allows you to specify the value of parameter "inp" also by key
entry.
Procedure
I.
C.
The operation of
causes the product to enter the monitor state. In the monitor
state, press the U key instead of the operation of
"T" will starts blinking, indicating the product is in teaching mode.
Key entry permits the actual process value to be displayed on the main indi-
cator.
J.
Press the U key again.
The actual process value is set as the input value and then the product will
return to the monitor state.
Pressing the M key instead of the U key in teaching mode cancels the
teaching mode and the display on the main indicator changes to the next
parameter.