Scaling
Scaling is to convert sampled input values to process values in sequence using a
predetermined scaling formula.
Scaling allows conversion of input values to process values in easy-to-understand
notation.
The scaling formula for pulse input is as follows.
Where;
INP:
DSP:
inp:
dsp:
Enter INP and DSP to specify the scaling factor.
Input pulse frequency (Hz) corresponding to process value DSP
Process value corresponding to input pulse frequency INP
Input pulse frequency (Hz)
Process value corresponding to inp
6-3 Measurement (K3MA-F)