CHAPTER 5 OPERATION
5-8
Available OUT set values and their indications are as follows.
OUT set value
Indication
OUT1 value
out1
OUT1 upper-limit
out1.h
value
OUT1 lower-limit
out1.l
value
OUT2 value
out2
OUT2 upper-limit
out2.h
value
OUT2 lower-limit
out2.l
value
(With K3MA-L, OUT2 value, OUT2 upper-limit value, and OUT2 lower limit value
are not available.)
For details of comparative output, refer to "6-5 Comparative Output".
Description
When the process value increases or
decreases to this value, comparative output
1 is provided.
When the process value falls outside-the-
range specified by these values, compara-
tive output 1 is provided.
When the process value increases or
decreases to this value, comparative output
2 is provided.
When the process value falls outside-the-
range specified by these values, compara-
tive output 2 is provided.