Appropriate setting of the
"move-to-protect-level
time"
parameter
allows
you
to
change the time required for
the product to move to the
protect level.
The
move-to-protect-level
time is factory set to 5
seconds.
Procedure
A.
When the product is at the operation level, press
the L+M keys and hold them down for at least
five seconds to enter the protect level.
• "p" will appear on the level indicator, indicating
the product has entered the protect level.
B.
Press the M key several times until the desired
parameter appears on the main indicator
C.
Press the S key to display the set value of the
parameter on the main indicator.
• The current set value will appear on the main
indicator
D.
Press the S key again.
• The current set value will start blinking, indicat-
ing the product is in the change state.
E.
Use the U key to change the set value.
F.
Press the M key to go to the next parameter.
• The change is saved.
G.
Press the L+M keys and hold down them for at
least one second to return to the operation level.
5-9 Key Protect Setting