2. OPERATION
2.15.4

How to use the input/output logs

The [I/O LOGS] display logged data for input/output information for serial ports and
LAN connections. You can export the logged data to an external flash memory.
The following keys have specific functions when a log screen appears.
Key
or
ENT
MENU ESC
Saved log files are automatically named in the following format:
This
equipment's
name
The log data which can be saved depends on the monitor type selected.
[DATA1] to [DATA5] - Serial data
Selected port and port's baud rate
2-30
Close the log and return to the [I/O] menu.
Toggle input and output log displays.
Press with external flash memory connected: start/pause saving the log.
Close the logs and the [I/O] menu.
The log type
Tx = ouput
Rx = input
The logged port. Displayed in the filename as follows:
DATA 1 to DATA 5 : Data from serial port 1 to 5.
Network
CANbus
RAW
Function
Time and date when the log was saved.
Displayed in YYYYMMDDHHMMSS
format.
: Data from the connected LAN network.
: PGN data from the CAN bus network.
: Raw data from the connected antenna.
Currently displayed data
TX = Output data
RX = Input data
USB status
No USB = No external
flash memory connected.
SAVING = Saving log
data to external flash
memory.
STOP SAVING = Flash
memory connected, no
log data currently being
saved.
Logged input/output data
is displayed here.