7. Secure the cable to the cable clamp, referring to the figure below.
Supplied cable
Z-#26X2P+0.3SQX1PL
With three cable ties
Cable clamp
Cable clamp
Cable tie
Cable tie
Cable
gasket
Secure the cable gasket also
with a cable tie.
Note: In cases where the WAGO connector is connected to the cable before the cable
is passed through the cable clamp, the cable clamp can be adjusted to allow connec-
tion. Adjusting the cable clamp as outlined in the figure below voids the IPx5 water-
proof rating of the clamp and the unit.
Cut along "V"-shaped
indent using a wire
cutter or similar tool.
To keep the IPx5 rating, remove the WAGO connector, then repeat the procedure above.
Top view of cable clamp
Equivalent cable for JIS cable (TTYCSLA-4)
Without Water Proof Kit
With two cable ties
Cable clamp
Cable clamp
Cable tie
Cable tie
Slot
Wind cable ties through the slots.
1. INSTALLATION
With Water Proof Kit
With a single cable tie
Cable clamp
Cable clamp
Cable tie
Cable tie
Slot
Cable
gasket
Wind a cable tie outside of the
cable clamp.
Slide the clamp over
the cable.
1-21