Product Description
5.3 Cabinet Details
Figure 5-19
Cell Bypass Operation
5.3.4

Control Section

The Control Section is located in front of the I/O Section and contains the NXG II Controller,
low voltage apparatus, and the auxiliary voltage disconnect switch; the Control Door is
considered part of this section in reference to the "A" and "B" drawings. The door in the
control section is hinged so that it can swing open 150 degrees to allow access to the
input/output section for purposes such as terminating medium voltage cables. Upon opening
the control door, two Cell Section Components polyglass barriers are encountered as
describe previously. In addition, the terminal blocks are accessible with the door in the open
position. See Table "Control Section Components" for the components found in this section.
Table 5- 12
Control Section Components
Component Label
SCB
SW2
DCR
CPS
DS1, AUX2
LFR
EPS
IOB
80
Part Description
NXG II: Signal Conditioning Board
Latch Fault Relay Reset
NXGII, Digital Card Rack
Slot 1: Keypad Interface Board
Slot 2: Single Board Computer
Slot 3: BGA Modulator with 12 Fiber Optic Ports
Slot 4: Reserved
Slot 5: Analog I/O Cable Assembly
Slot 6: System I/O Board
Slot 7: Digital I/O Cable Assembly
Slot 8: Communications Board
Control Power Supply
Auxiliary Voltage Disconnect and Position Switch
Latch Fault Relay
Encoder Power Supply (optional)
NXG II, Input/Output Breakout