Application and Operation
6.15 Tool Suite
Status
● Programmable display variables
● Fault and Alarm indicators (traffic lights: red = fault, yellow = alarm, green = none)
Control (** only if enabled by SOP)
● Manual Start Button
● Stop Button
● Fault Reset Button
6.15.2
NXG Debug Utility
The NXG Control provides a built in debug function that provides real time status of various
parameters, measured values, and calculations. This function is wholly contained in the NXG
control, and user access is available from three separate ports:
● NXG CPU Video port using a standard VGA monitor with a standard PC keypad
● Ethernet port using the Debug Utility provided by the NXG Tool Suite
● RS232 Serial Port
The debug utility is intended for use during test, commissioning, and troubleshooting of the
drive.
The NXG Tool Suite is a PC-based application software package that includes the Drive
Host, Debug Utility, System Program Compiler, and Configuration tools for the NXG control.
Note that the Drive Host and Debug utility communicate with an NXG drive via an Ethernet
link. The System Program compiler and Configuration Update Tools are PC applications.
Please refer to
of the Tool Suite software package.
See also
Data Logs (Page 132)
150
– Pick list selectable variables, same as drive keypad display list
– First 4 synchronized to keypad display
connected to the CPU card for navigating displays
NXG ToolSuite Software User Manual A1A902291
for a complete description
Operating Instructions, Version AE 12/2009, A5E01454341C
Product User Manual