Storage Health Inspection (Shi) - HighPoint RocketRAID 4520 User Manual

Rocketraid 4500 series
Hide thumbs Also See for RocketRAID 4520:
Table of Contents

Advertisement

Storage Health Inspection (SHI)

The Storage Health Inspector (SHI) monitors each individual disk's health. Monitoring
disk SMART attributes can prevent critical RAID failures from occurring.
This section covers the following:
Enabling SMART Monitoring
Disabling SMART Monitoring
Changing HDD Temperature Threshold
Enabling SMART Monitoring
To access the SMART attributes of an individual disk:
1. Log in to WebGUI (default user: RAID password: hpt).
2. Select the proper controller using the drop down menu on the top left.
3. Click the SHI tab.
4. Click SMART on the desired disk.
5. Click Enable to enable SMART monitoring.
Disabling SMART monitoring
You have the option to disable SMART monitoring on each individual disk:
1. Select the proper controller using the drop down menu on the top left.
2. Click the SHI tab.
40