Quick Start Guide
Loop / Power
U
= 30V
i
U
= 17.5 V
i
I
= 300 mA
i
I
= 380 mA
i
P
= 1.0 W
i
P
= 1.3 W
i
P
= 5.32 W
i
C
= 0.012 μF
i
C
= 0
i
L
= 0
i
L
= 10 μH
i
CCoE Certifications
EW Flame-Proof
Ex d IIC T5 or T6
IW Intrinsic Safety
Ex ia IIC T4
Combinations of Certifications
Stainless steel certification tag is provided when optional approval is specified.
Once a device labeled with multiple approval types is installed, it should not be
reinstalled using any other approval types. Permanently mark the approval label
to distinguish it from unused approval types.
K1
E1, I1, N1, and ND combination
K2
E2 and I2 combination
K5
E5 and I5 combination
K6
I6 and E6 combination
K7
E7, I7, and N7 combination
KA
E1, I1, E6, and I6 combination
KB
E5, I5, E6, and I6 combination
KC
E1, I1, E5, and I5 combination
KD
E1, I1, E5, I5, E6, and I6 combination
22
Groups
HART / F
fieldbus / Remote Display / Quick Connect / HART
OUNDATION
Diagnostics
FISCO
HART / F
fieldbus / Remote Display / Quick Connect / HART
OUNDATION
Diagnostics
FISCO
HART / Remote Display / Quick Connect / HART Diagnostics
F
fieldbus
OUNDATION
FISCO
HART
F
fieldbus / FISCO
OUNDATION
F
fieldbus
OUNDATION
HART