The function description of the machine provides the basis when engineering the drive
application. The definition of the components is based on physical interdependencies and is
usually carried-out as follows:
step
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Configuration begins with the mechanical interface to the machine. A suitable motor is
selected according to the specified torques and speeds. A matching power unit is then also
chosen. Depending on the requirements of the machine, the motor is supplied as a single
drive via a Power Module or within a multi-motor drive group via a Motor Module. Once the
basic components have been defined, the system components for matching to the electrical
and mechanical interfaces are selected.
The SIZER configuring tool helps the user to select the correct components quickly and
easily. The user enters the relevant torque and speed characteristics and SIZER then guides
him confidently through the configuring process, identifying suitable motors and matching
SINAMICS power units and other system components.
Synchronous Motors 1FK7
Configuration Manual, (PFK7S), Edition 12.2006, 6SN1197-0AD16-0BP1
Description of the engineering activity
Clarification of the type of drive
Definition of the load, calculation of max. load torque
Specification of the motor
The SINAMICS Motor Module is selected
Steps 3 and 4 are repeated for additional axes
The required DC link power is calculated and the SINAMICS Line Module is
selected
Specification of the required control performance and selection of the Control
Unit, definition of component cabling
The line-side options (main switch, fuses, line filters, etc.) are selected
Additional system components are defined and selected
The current demand of the 24 V DC supply for the components is calculated
and the power supplies (SITOP devices, control supply modules) specified
The components for the connection system are selected
The components of the drive group are configured to form a complete drive
Required cable cross sections for power supply and motor connections
Mandatory installation clearances