Cable

MAS 2600 -XXX-XX-X/XX
Two types of transducer cables are available. The standard cable for applications with temperatures
up to 80C, and high temperature cable for applications with temperatures up to 125C. The trans-
ducer cable is delivered in whole meters.
To make the MAS 2600 transmitter easy to install, and for later service purposes, the transducer
cable should be as short as possible, though considering the position of the transducer and amplifier
box.
Note!
16
Maximum cable length:
Safe area
Standard cable 300 m
High temperature cable 300 m
Hazardous area
Standard cable 44 m
High temperature cable 34 m