Connecting

5.1 SITRANS FUE380 and FUS380

5.1
SITRANS FUE380 and FUS380
Power for pulse output from SITRANS FUE380 and FUE380 is automatically supplied via
energy calculator terminals 10 and 11:
FUE380/FUS380 terminal
56
57
56
57
Note
Use shielded cable. Connect shield to grounding at flowmeter (e. g. the clamp of FUE380).
For connection of flowmeter, see flowmeter operating instructions.
5.2

SITRANS F M MAG 5000/6000

When MAG 5000/6000 and SITRANS FUE950 are connected as a heat meter, 2 resistors
are required to obtain a correct transmission of pulses.
The 2 resistors must be mounted between terminals 57 and 58 in the MAG terminal socket.
Resistors are part of neither delivery nor accessories list.
MAG 5000/6000 terminal
57
58
24
FUE380/FUS380
FUE950 terminal
10
11
FUE950 terminal
10
11
Operating Instructions, 01/2010, SFIDK.PS.022.F4.02