  • Page 1 Model 9135 SNMP Managed 10/100/1000 Ethernet Switch User Manual...
  • Page 3 EdgeAccess Universal Chassis System CAUTION! This product may contain a laser diode operating at a wavelength of 1300nm - 1600nm. Use of optical instruments (e.g., collimating optics) with this product may increase eye hazard. Use of controls or adjustments, or performing procedures other than those specified herein may result in hazardous radiation exposure.
  • Page 4 Perkins and any unauthorized use or disclosure of such drawings, specifications and information is prohibited. Canoga Perkins reserves the right to change or update the contents of this manual and to change the specifications of its products at any time without prior notification. Every effort has been made to keep the information in this document current and accurate as of the date of publication or revision.
  • Page 5: Table Of Contents

    EdgeAccess Universal Chassis System Table of Contents Chapter 1 Overview ....................1-1 Data Switch Features ......................1-1 Hardware Management Features .................... 1-2 Chapter 2 Setup and Installation................2-1 Install the 9135 ........................2-1 LEDs ............................2-4 Chapter 3 Management ..................3-1 Set Up the Serial Port ......................
  • Page 6 EdgeAccess Universal Chassis System Appendix A Warranty....................A-1 Appendix B Acronyms.................... B-1 List of Figures Figure 1. 9135 SNMP Managed Ethernet Switch ................1-1 Figure 2. SW1 on UTP Copper Interface ...................2-1 Figure 3. SW1 on 100 Base Modules, Fiber Optic Interface .............2-2 Figure 4.
  • Page 7 EdgeAccess Universal Chassis System List of Tables Table 1. SW1 Settings, UTP Copper Interface .................. 2-1 Table 2. SW1 Settings, 100 Base Modules, Fiber Optic Interface ............ 2-2 Table 3. SW1 Settings, 1000 Base Modules, Fiber Optic Interface ..........2-3 Table 4.
  • Page 8 EdgeAccess Universal Chassis System Model 9135 10/100/1000...
  • Page 9: Chapter 1 Overview

    Chapter 1 Overview The Canoga Perkins EdgeAccess 9135 is an SNMP Managed, two-port Ethernet Switch that provides Managers and Network Analysts with a modular-managed 10/100 or 1000 Mbps LAN platform. See Figure 1. The 9135 switch supports two 10, 100, or 1000 Mbps interface modules. The hot- swappable interface modules provide these options: •...
  • Page 10: Hardware Management Features

    EdgeAccess Universal Chassis System Hardware Management Features The 9135 includes these hardware features for switch management: • Alarm relay contacts that can transmit these fault conditions for each port. • Loss of link integrity • Remote fault • Power failure •...
  • Page 11: Chapter 2 Setup And Installation

    1. Unpack the 9135. Keep the shipping container until the unit is installed and fully operational. In the unlikely event that the unit is defective, contact Canoga Perkins Customer Service for a return authorization number (RMA) and instructions on return shipment. For details, see Appendix A.
  • Page 12: Figure 3. Sw1 On 100 Base Modules, Fiber Optic Interface

    EdgeAccess Universal Chassis System 3. On the 100 Base modules, fiber optic interface (9100-44x, -54x, -64x, or -74x), set SW1 for your system; see Figure 3 and Table 2. Figure 3. SW1 on 100 Base Modules, Fiber Optic Interface Table 2. SW1 Settings, 100 Base Modules, Fiber Optic Interface Switch Name Full-duplex...
  • Page 13: Table 3. Sw1 Settings, 1000 Base Modules, Fiber Optic Interface

    EdgeAccess Universal Chassis System Table 3. SW1 Settings, 1000 Base Modules, Fiber Optic Interface Switch Name Enable LLF Disable LLF Enable LLE Disable LLE 5. Mount the 9135 in a rack or as a standalone unit. • Use the standard rackmount kit with brackets and screws to install the 9135 in a 19-inch rack or use the optional 23-inch rackmount kit.
  • Page 14: Leds

    EdgeAccess Universal Chassis System Dirty optical connectors are a common cause of link loss or attenuation problems, especially for single mode fiber (SMF). Clean the connectors before plugging in a cable and whenever there is a significant or unexplained light loss. To prevent contamination, always install protective dust covers on unused fiber optic connectors.
  • Page 15: Table 5. 9135 Interface Module Leds

    EdgeAccess Universal Chassis System Table 5. 9135 Interface Module LEDs Status Indicates Tx (Transmit) No transmit activity Green Current transmit activity Transmitter disabled due to LLF or LLE Lnk (Link) No optical link Green Optical link established Col (Collision) Amber Collision occurred No data collisions No receive activity...
  • Page 16 EdgeAccess Universal Chassis System Model 9135 10/100/1000...
  • Page 17: Chapter 3 Management

    EdgeAccess Universal Chassis System Chapter 3 Management Configure the 9135 through the management software. For your first session, you must use HyperTerminal; you can set up Telnet access through the Host Table/SNMP Settings menu. Set Up the Serial Port The first time you access the 9135, use a terminal port connection and HyperTerminal on your PC. These steps briefly describe how to set up your PC for a terminal connection.
  • Page 18: Using The 9135 Management Program

    EdgeAccess Universal Chassis System Chassis and slot numbers Model number Status reports Change options Screen navigation instructions Messages and urgent status Figure 5. Typical 9135 Screen Not all screens and menus provide options that you can change. Some menu items reach screens that only report status, such as revision numbers, module type, or alarms.
  • Page 19: System Menu

    EdgeAccess Universal Chassis System Main Menu System Switch Configuration Port Information Reports Diagnostics Restore Defaults Restart Logout Figure 7. Main Menu The Main Menu provides access to all functions for the 9135: setup, diagnostics, and reports. See Table 6. Table 6. Main Menu Options Menu Item Description 1.
  • Page 20: Ip Settings

    EdgeAccess Universal Chassis System Table 7. System Menu Options Menu Item Description 1. IP Settings Set the IP parameters 2. Host Table / SNMP Settings Set up the Host Table and SNMP access 3. SLIP Port Settings Set up for Serial Line Interface Port (SLIP) access 4.
  • Page 21: Table 8. Ip Settings Menu Options

    EdgeAccess Universal Chassis System Table 8. IP Settings Menu Options Menu Item Description 1. Local IP Address Set the network address of the 9135. The first octet of the IP address defines the class, or how the IP address is split between the network ID and the host ID.
  • Page 22: Host Table / Snmp Settings

    EdgeAccess Universal Chassis System 3.4.2 Host Table / SNMP Settings Use the Host Table and SNMP Settings menu to set access levels for hosts and destinations for traps. You can set the access and trap community for various IP addresses. By default, a trap community is "public"...
  • Page 23: Slip Port Settings

    EdgeAccess Universal Chassis System HOST Table/SNMP Settings SNMP Access Trap Trap IP Address Access Level Community Port 1. 172.16.142.1 SNMP only read/write/trap public 2. 172.16.142.4 SNMP only read/write/trap public 3. 172.16.142.3 SNMP only read/write/trap public 4. 192.0.0.3 SNMP only read/write/trap public 5.
  • Page 24: Passwords

    Select Direct, for SLIP mode, or Modem 2. Init Modem at Startup Select yes or no 3. Modem Init String The default string is ats0=1; do not change unless Canoga Perkins technical assistance advises 4. Password Enable Select yes or no 5.
  • Page 25: Figure 12. Passwords Menu

    EdgeAccess Universal Chassis System 3. At the prompt, type the new password, up to 18 characters, then type it again to confirm it and save it. Note: All letters, numbers, and characters are legal; the password is case sensitive. Passwords You are logged in as : Change Supervisor Password Change Manager Password...
  • Page 26: Switch Configuration And Spanning Tree

    EdgeAccess Universal Chassis System Menu and Selection Minimum Access Menu and Selection Minimum Access Host Table / SNMP Settings Menu Port n Details Menu Read Community Supervisor Clear Counters User Write Community Supervisor Traps Log Menu Send Alert Traps Supervisor View Previous Page User SLIP Port Settings Menu...
  • Page 27: Global Spanning Tree Parameters

    EdgeAccess Universal Chassis System A small test network Spanning Tree from source (C) Figure 14. Typical Spanning Tree Application. Note: For details on the Spanning Tree Algorithm, see the IEEE 802.1 specifications. The Spanning Tree menu offers reports and menus for viewing and setting various STP parameters for the 9135.
  • Page 28: Port Spanning Tree Parameters

    EdgeAccess Universal Chassis System Global Spanning Tree Parameters 1. Enable Spanning Tree 2. Priority 3. Hello Time (sec) 4. Forward Delay (sec) 5. Max Age (sec) 6. Main Menu Figure 16. Global Spanning Tree Parameters Menu Table 13. Global Spanning Tree Parameters Menu Options Menu Item Description 1.
  • Page 29: Figure 17. Port Spanning Tree Parameters Report And Menu

    EdgeAccess Universal Chassis System Global Spanning Tree Parameters State : forwarding Designated Root : 00 00 00 00 00 00 00 00 Designated Cost Designated Bridge : 00 00 00 00 00 00 00 00 1. Change Port 2. Priority : 128 3.
  • Page 30: Spanning Tree Report

    EdgeAccess Universal Chassis System 3.5.3 Spanning Tree Report The Spanning Tree Report screen shows the current conditions for the bridge network. See Figure 18 and Table 16. To access the Spanning Tree Report, see Figure and follow these steps: 1. From the Main menu, type 2, Switch Configuration and press <Enter>. 2.
  • Page 31: Port Information

    EdgeAccess Universal Chassis System Port Information The various Port Information and Statistics screens shows status for the ports on the 9135. • Ports information follows the front panel LEDs; see Figure 19. • Port n Statistics shows standard information about the data flow through one port and provides options to update parameters;...
  • Page 32: Figure 20. Port N Information Screen

    EdgeAccess Universal Chassis System Port 1 Information Link : yes LLF Hw Switch : disabled Frames Received : 282356856 AUT Hw Switch : disabled Frames Sent : 4472214 FDX Hw Switch : enabled Data Rate : 100 Mpbs 100 Hw Switch : enabled Duplex : full duplex...
  • Page 33: Reports

    EdgeAccess Universal Chassis System Reports The Reports Menu provides access to a brief description of the 9135, the traps log, and the Fdb log. See Figure 23. Reports Description Traps Log Fdb Log Main Menu Figure 23. Reports Menu 3.7.1 Description Report Screen The Description screen lists the device type, software revisions stored in the Flash 1 and Flash 2 memory locations and which revision is active, and the time since last restart.
  • Page 34: Fdb Log Screen

    EdgeAccess Universal Chassis System Traps Log Count Time 0 days 00:11:07 Trap Type 0 days 00:00:00 Cold Start () 0 days 00:00:01 Link Up (1) Of: 2 1. View Previous Page 2. View Next Page 3. Clear The Log 4. Main Menu Figure 25.
  • Page 35: Diagnostics

    EdgeAccess Universal Chassis System Fdb Log Count Port Status 00 C0 EE D0 90 5B learned 00 D0 B7 47 BD 58 learned 00 D0 B7 83 34 9D learned 00 D0 B7 83 45 CB learned 00 E0 63 75 3D 34 learned 00 E0 DB 02 BD 4A learned...
  • Page 36: Restore Defaults

    EdgeAccess Universal Chassis System Ping Ping Address Ping Count Start Pinging Main Menu Figure 28. Ping Menu Restore Defaults Use the Restore Defaults option to restore all configurable settings to factory defaults except this network information: • IP Address (Network) •...
  • Page 37: Logout

    EdgeAccess Universal Chassis System Restart System 1. System 2. Switch Configuration 3. Port Information 4. Reports +---------------------------------------------+ Restart Unit. Are you sure? (Y/N) : +---------------------------------------------+ 8. Logout Figure 30. Restart Unit Menu 3.11 Logout When passwords are set to keep the system secure, log out at the end of each session. To restore the system defaults, follow this step: 1.
  • Page 38: Update The Software Through Ftp

    EdgeAccess Universal Chassis System 7. Start the download. The process sends the upgrade directly to the inactive Flash location. 8. When the TFTP client indicates the transfer is complete, close the TFTP program. 9. To activate the new software revision, reset the 9135, then return to the Description screen to verify that the new Software Revision is listed as active and the old version remains in the inactive Flash.
  • Page 39 EdgeAccess Universal Chassis System 13. When the transfer is complete, a successful message appears. At the prompt, enter quit to close the FTP connection. 14. To activate the new software revision, reset the 9135, then return to the Description screen to verify that the new Software Revision is listed as active and the older version remains in the inactive Flash.
  • Page 40 EdgeAccess Universal Chassis System 3-24 Model 9135 10/100/1000...
  • Page 41: Chapter 4 Slip Connection

    EdgeAccess Universal Chassis System Chapter 4 SLIP Connection You can connect a dial-up modem to the DCE port on the SNMP Management Module in order to manage the 9135 through SNMP. Configuring the 9135 for SLIP Connect a DCE to DTE serial modem cable between the 9135 and the PC or terminal, then follow these steps: 1.
  • Page 42: Launching A Slip Connection

    EdgeAccess Universal Chassis System 6. On the Basic tab, enter a name and the phone number for the 9135, then from the Dial using drop- down, select the modem. 7. On the Server tab, from the Dial-Up Server Type drop down, select SLIP: Internet, then check TCP/IP and click TCP/IP Settings.
  • Page 43: Chapter 5 Specifications

    EdgeAccess Universal Chassis System Chapter 5 Specifications Switch Specifications Switching Characteristics Bridging: Per IEEE 802.1d Spanning Tree Address Table: Maximum 1000 MAC addresses entry Forwarding Rate: 148,800 packets-per-second maximum per port Buffer Memory: 1 MB per port Management Board Characteristics In-Band Support: SNMP, TELNET, TFTP, FTP, BOOTP MIBs Supported:...
  • Page 44: 9135 Ports And Pinouts

    EdgeAccess Universal Chassis System 9135 Ports and Pinouts Table 17. Terminal Port, Female DE-9 Signal 1, 4, 8, 9 Not Used RXD In TXD Out Common Ground Table 18. SLIP Port, Male DE-9 Signal DCD In RXD In TXD Out DTR Out Common DSR In...
  • Page 45: Regulatory Compliance And Referenced Documents

    EdgeAccess Universal Chassis System Regulatory Compliance and Referenced Documents Complies with these regulations: • ETL, cETL (CAN/CSA-C22.2 No.60950/UL 60950) • EN 60950, IEC 60950 • CDRH CFR21/EN60825-1 • FCC Part 15B, Class A, IC CS-003, C-Tick (AS/NZS 3548) • EN 55022 •...
  • Page 46: Edgeaccess Universal Chassis System

    EdgeAccess Universal Chassis System 100BASE FX Fiber Optic Field-Interchangeable Interfaces 9100-441 100BASE FX 1310 nm MM LED with ST connectors, 11 dB w/ 62.5/125 Fiber 9100-442 100BASE FX 1310 nm MM LED with Duplex SC connectors, 11 dB w/ 62.5/125 Fiber 9100-641 100BASE FX 1310 nm SM Laser with ST connectors, 10 dB w/ 8 or 10/125 Fiber 9100-642 100BASE FX 1310 nm SM Laser with Duplex SC connector, 10 dB w/ 8 or 10/125 Fiber 9100-647 100BASE FX 1310 nm SM Laser with ST connectors, 26 dB w/ 8 or 10/125 Fiber...
  • Page 47 EdgeAccess Universal Chassis System 10 BASE FL SM 20 dB Emitter Type: Laser diode Wavelength: 1310 nm nominal Receive Sensitivity: -34 dBm minimum Transmit Launch Power: -6 dBm maximum -15 dBm minimum Overdrive: -10 dBm Loss Budget: 20 dB minimum Optical Connector: ST or FC/PC 10 BASE FL SM 25 dB...
  • Page 48 EdgeAccess Universal Chassis System 100 BASE FX SM 10 dB Emitter Type: Laser diode Wavelength: 1310 nm nominal Receive Sensitivity: -31 dBm minimum Transmit Launch Power: -14 dBm maximum -20 dBm minimum Overdrive: -8.0 dBm Loss Budget: 10 dB minimum Optical Connector: Duplex SC or ST 100 BASE FX SM 26 dB...
  • Page 49 EdgeAccess Universal Chassis System Gigabit Single Mode (SM) 1310 nm LX Emitter Type: Laser Diode Wavelength: 1310 nm nominal Receive Sensitivity: -18 dBm minimum Transmit Launch Power: -3.0 dBm maximum -11.0 dBm minimum Overdrive: -3.0 dBm maximum Loss Budget: 7.0 dB minimum Optical Connector: Duplex SC Gigabit Single Mode (SM) 1310 nm LD (DFB)
  • Page 50 EdgeAccess Universal Chassis System Model 9135 10/100/1000...
  • Page 51: Appendix A Warranty

    Warranty Limited Lifetime Warranty Effective July 1, 2005 and After, Canoga Perkins warrants that, at the time of sale, and, for its lifetime, with certain exceptions noted below, every Canoga Perkins' labeled product purchased will be free from defects in material and workmanship for its lifetime, if properly installed and used in conformity to Canoga Perkins' published specifications.
  • Page 52: Return Policy

    EdgeAccess Universal Chassis System Limitations Canoga Perkins may at its sole discretion modify its Limited Warranty at any time and from time to time. Other than those expressly stated herein, THERE ARE NO OTHER WARRANTIES OF ANY KIND, EXPRESSED OR IMPLIED, AND SPECIFICALLY EXCLUDED BUT NOT BY WAY OF LIMITATION, ARE THE IMPLIED WARRANTIES FOR FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY.
  • Page 53: Appendix B Acronyms

    EdgeAccess Universal Chassis System Appendix B Acronyms BOOTP Boot Protocol (a TCP/IP protocol) BPDU Bridge Protocol Data Unit Clear To Send Data Communications Equipment Data Signal Ready Data Terminal Equipment Data Terminal Ready Full-duplex Link Loss Echo Link Loss Forwarding Link Normally Closed (relays and switches) Normally Open (relays and switches)
  • Page 54 CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth, California 91311-6008 USA Phone: (818) 718-6300 FAX: (818) 718-6312 Web Site: www.canoga.com Email: fiber@canoga.com...

Table of Contents