10. To enable a remote computer to dial in

When the user or installer wants to dial in to the installation from their JA-60U modem equipped computer or JA-60E keypad (see 15.),
the following parameters should be programmed in the control panel's telephone dialer.
The most convenient programming of the dialer is via a connected PC using the Comlink software (see 14). Programming can also be
performed by entering programming sequences from the system keypad while in the control panel programming mode:
Enter the programming mode (entering F 0 SC - SC = Service Code, factory default SC=6060), indicated by a „P" on the display.
This can only be done while the panel is disarmed.
The programming sequences can be entered from the keypad. Any unfinished sequence can be terminated by N key.
To exit the programming mode, press the N key („P" will turn off).
Dialing in parameters
Function
Incoming call reaction
Remote access code (8 digits)

10.1. Reaction to an incoming call

This sequence sets how the communicator will react to incoming calls on the telephone line. This setting is important for
access from a remote computer.
0 5 x
x can be
0 - never answer
1 - answer after second call = after 1 or 2 rings are detected, there must be a pause of 10 - 45 sec-
2, 3, 4, 5, 6 - answer after 2
Note: Remote access connection can also be enabled by the alarm system user (regardless of the above setting) by en-
tering code 89 during service or user mode, when a remote call rings. If you use another telephone set on the same tele-
phone line, it should be switched to a tone dial mode.
Factory setting: 0 = never answer

10.2. Remote access code setting

In order to access the panel from a remote computer or JA-60E keypad, it is necessary to authorize the access with an 8-
digit access code. This code is compared with the one programmed in the control panel. If the remote computer tries to
access the panel with an other code, the connection will be terminated immediately and a wrong code alarm will triggered
on the control panel. Store your access code to the control panels by entering:
0 7 xxxxxxxx
x x . . . . . x - any 8 digits access code
Factory setting: 00000000

11. Factory default RESET

If you forgot the control panel codes or you have a control panel which is currently not under factory default setting, per-
form the following procedure:
disconnect the AC adapter, back up battery and wait 30 seconds.
reconnect the back up battery and close the control panel cover
press and hold the 6 key on the control panel while reconnecting the AC adapter.
when "−" is displayed, enter 060 (within 10 seconds)
reset is confirmed with "P" (panel is in programming mode)
Note: this procedure resets the factory default settings (see table 8). The Master code will be 1234, Service code 6060
and all user codes, detectors, controllers and other enrolled items will be forgotten. All telephone numbers will be erased.
The reset will not erase event memory and information about the reset will be recorded there.
Warning: if the Master code is forgotten when reset is disabled (with sequence 280 - see part 8.9.), the control panel re-
set will be possible only by the manufacturer.
Alarm system JA-60 "COMFORT"
onds. The dialer will then answer on the very first ring of the second call. This setting can be used
to bypass an answering or facsimile machine connected to the same line. This "Second Call" fea-
ture is supported by the Comlink software
sequence
0=disabled, 1= second
0 5 x
call, 2-6 = after ring No. 2
0 7
xxxxxxxx
nd
rd
th
th
th
, 3
, 4
, 5
or 6
ring
- 22 -
factory d.
options
disabled
- No.6
any 8 digits code
00000000
note
sequence: 05
sequence: 07