To Enable A Remote Computer To Dial In; Reaction To An Incoming Call; Remote Access Code Setting - jablotron MAESTRO JA-65 Installation Manual

Hide thumbs Also See for MAESTRO JA-65:
Table of Contents

Advertisement

15. To enable a remote computer to dial in

When the user or installer wants to dial in to the installation from their JA-60U modem equipped computer (see 20.), the following
parameters should be programmed in the 65X control panel's telephone dialer.
The most convenient programming of the dialer is via a connected PC using the Comlink software (see 19). Programming can also be
performed by entering programming sequences from the system keypad while in the control panel programming mode:
Enter the programming mode (entering F 0 SC - SC = Service Code, factory default SC=6060), indicated by a „P" on the LED
display. This can only be done while the panel is disarmed.
The programming sequences can be entered from the keypad. Any unfinished sequence can be terminated by the N key.
To exit the programming mode, press the N key („P" will turn off).
Dialing in parameters
Function
Incoming call reaction
Remote access code (8 digits)

15.1. Reaction to an incoming call

This sequence sets how the communicator will react to incoming calls on the telephone line. This setting is important for
access from a remote computer.
0 5 x
x can be
0 - never answer
1 - answer after second call = after 1 or 2 rings are detected, there must be a pause of 10 - 45
2, 3, 4, 5, 6 - answer after 2
Notes: Remote access connection can also be enabled by the alarm system user (regardless of the above setting) by
entering code 89 during service or user mode, when a remote call rings. If you use another telephone set on the same
telephone line, it should be switched to a tone dial mode.
Factory setting: 0 = never answer

15.2. Remote access code setting

In order to access the panel from a remote computer, it is necessary to authorize the access with an 8-digit access code.
This code is compared with the one programmed in the control panel. If the remote computer tries to access the panel
with an other code, the connection will be terminated immediately and a wrong code alarm will triggered on the control
panel. Store your access code to the control panels by entering:
0 7 xxxxxxxx
x x . . . . . x - any 8 digits access code
Factory setting: 00000000
sequence
0 5 x
0 7
xxxxxxxx
seconds. The dialer will then answer on the very first ring of the second call. This setting can be
used to bypass an answering or facsimile machine connected to the same line. This "Second
Call" feature is supported by the Comlink software
options
0=disabled, 1= second call, 2-6 =
after ring No. 2 - No.6
any 8 digits code
nd
rd
th
th
th
, 3
, 4
, 5
or 6
ring
factory d.
note
disabled
00000000
sequence: 05
sequence: 07

Advertisement

Table of Contents
loading