12. Safety devices
Type of protection
Circuit protection
Fan motor protection
Compressor protection
Protection form
Current fuse
(PCB)
Protector
(PCB)
Thermal protection program
Thermal protection program
(Compressor temp.)
Thermal protection program
(Discharge temp.)
- 324 -
AOYG36LBLA5
250 V, 10 A
250 V, 5 A
400 V, 5 A
250 V, 3.15 A
500 V, 45 A
115±15 °C
Activate
Fan motor stop
Reset
Fan motor restart
Activate
Compressor stop
Reset
Compressor restart
Activate
Compressor stop
After 3 minutes
Reset
and 110 °C less than
Compressor restart
Model
70 °C
108 °C
80 °C
110 °C