Fujitsu AUYG07LVLA Design & Technical Manual page 26

Multi: 5, 6 rooms type
Hide thumbs Also See for AUYG07LVLA:
Table of Contents

Advertisement

Model name
Power supply
Available voltage range
Capacity
Input power
Running current
Cooling
Airflow rate
Fan
Heating
Type × Q'ty
Motor output
Cooling
Sound pressure level *
Heating
Cooling
Sound power level
Heating
Dimensions (H × W × D)
Fin pitch
Heat exchanger type
Rows × Stages
Pipe type
Fin type
Material
Enclosure
Color
Net
Dimensions
(H × W × D)
Gross
Net
Weight
Gross
Liquid
Size
Connection
Gas
pipe
Method
Material
Drain hose
Size
Cooling
Operation range
Heating
Remote controller type
NOTES:
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer's anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
ASYG18LFCA
kW class
W
A
HIGH
MED
LOW
QUIET
3
m
/h
HIGH
MED
LOW
QUIET
W
HIGH
MED
LOW
QUIET
dB (A)
HIGH
MED
LOW
QUIET
dB (A)
mm
mm
Main: 2 × 18, Sub: 1 × 4
mm
kg
mm (in)
Ø12.70 (Ø1/2)
mm
°C
%RH
°C
- 18 -
ASYG24LFCA
1Ø 230 V ~50 Hz
198—264 V
5.0
37
0.33
900
740
620
550
900
740
620
550
Cross flow fan ×1
42
43
37
33
26
42
37
33
25
58
58
Main: 378 × 832 × 26.6
Sub: 84 × 832 × 13.3
Main: 1.2, Sub: 1.4
Main: 2 × 18, Sub: 1 × 4 + 1 × 4
Copper tube
Aluminum
Polystyrene
White
(Approximate color of Munsell N 9.25/)
320 × 998 × 238
329 × 1,090 × 420
14
18
Ø6.35 (Ø1/4)
Flare
PVC
Ø12 (I.D.), Ø16 (O.D.)
18 to 32
80 or less
16 to 32
Wireless (Wired [option])
ASYG24LFCC
7.0
69
0.53
1,120
900
740
620
1,100
900
740
620
65
49
42
37
33
48
42
37
33
64
64
Ø15.88 (Ø5/8)

Hide quick links: