Installing A Non-Hot-Plug Drive - HP ProLiant ML350e Gen8 User Manual

Hide thumbs Also See for ProLiant ML350e Gen8:
Table of Contents

Advertisement

Install the drive.
5.
Determine the status of the drive from the drive LED definitions
6.
page 19).
Install the front bezel (on page 24).
7.

Installing a non-hot-plug drive

CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
To install the component:
Power down the server (on page 22).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Remove the front bezel (on page 23).
3.
Place the server on its side.
4.
Remove the access panel (on page 24).
5.
If installed, remove the PCI air baffle (on page 26).
6.
Remove the system air baffle (on page 27).
7.
Remove any installed full-length PCI expansion board
8.
page 28)s.
Remove the fan modules and the fan blank (on page 29).
9.
If already installed, disconnect the drive cables from the rear of the drives.
10.
("Hot-plug drive LED
("Remove the full-length expansion
Hardware options installation 51
definitions" on
board" on

Hide quick links: