Raised Installation Framing - Single Sided
Determine the height of the platform based on where you want the
bottom edge of the glass to be, see below for unit dimensions. Maintain
minimum ceiling height shown in table. Build fireplace frame as shown.
A
Figure 4. Raised Installation Framing - Single Sided
D6315, DL6315
A
79 ½''
B
50 ⅜''
C
MAX 48''*
D
18''
E
2 1/4''
†
10
D
B
E
C
*24'' platform height requires
a minimum of 8' ceiling height.
The unit can be placed on a 48''
platform if a minimum of 10'
ceiling is attained.
†Mesurement is a 2x4 on side
and a 3/4'' plywood platform.
Raised Installation Framing - See Through
Determine the height of the platform based on where you want the
bottom edge of the glass to be, see below for unit dimensions. Maintain
minimum ceiling height shown in table. Build fireplace frame as shown.
A
Figure 4.b Raised Installation Framing - See Through
D6315ST, DL6315ST
A
79 ½''
B
50 ⅜''
C
MAX 48''*
D
18
/
''
7
16
E
2 1/4''
†
Installation
D
B
E
C
*24'' platform height requires
a minimum of 8' ceiling height.
The unit can be placed on a 48''
platform if a minimum of 10'
ceiling is attained.
†Mesurement is a 2x4 on side
and a 3/4'' plywood platform.
XG0221