Montigo DL6315 Installation & Maintenance Manual page 15

Distinction indoor gas fireplace, 40,000/50,000 btu/hr natural gas or propane gas
Table of Contents

Advertisement

Framing with Cool Wall Advantage
Below are basic instructions on the framing of the Cool Wall advantage kit. More detailed instructions including the installation diagrams are
included with the kit.
2015.73
2015.73
79.4
79.4
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
Figure 8.b.b Framing with Cool Wall Advantage
NAME
DATE
DRAWN
CF
26/05/2017
CHECKED
CF
1/19/2017
SIZE
DWG. NO.
THIRD ANGLE PROJECTION
SCALE:
XG0221
2x4 On Edge
2x4 On Edge
Steel Studs
Steel Studs
DIM ARE IN INCHES
MATERIAL
MATERIAL
FRACTIONAL
FINISH
FINISH
X.XX
WEIGHT (lbs)
WEIGHT (lbs)
X.XXX
ANGULAR:
BEND ALLOW.
BEND ALLOW.
UNLESS OTHERWISE SPECIFIED
ALL BENDS ARE 90
K-FACTOR
K-FACTOR
REV.
TV Kit Framing
1:32
1 OF 2
SHEET:
Main Vent
Main Vent
5" Dia Flex Vent
5" Dia Flex Vent
TV recess framing
DIM ARE IN INCHES
NAME
DATE
NAME
FRACTIONAL
1/32
1/32
DRAWN
DRAWN
CF
26/05/2017
CF
X.XX
.015
.015
1/19/2017
X.XXX
.005
.005
CHECKED
CHECKED
CF
CF
ANGULAR:
1
1
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PR
THIRD ANGLE PROJECTION
THIRD ANGLE PROJECTION
UNLESS OTHERWISE SPECIFIED
ALL BENDS ARE 90
The recess MUST
be made from
Non-Combustable
materials. Maintain
1" clearance
from venting to
combustibles.
12" min. from
fireplace opening
The recess must be made from Non-Combustable materials. Recess can
be increased beyond a 4" depth by using a 45° or 90° elbow in venting
after the minimum 3' upward distance is achieved, 1" clearance from
venting to combustibles must still be maintained.
Installation
1677.92mm
66.060in
1653mm
65in
Opening
5" Flex Vent Collars
781mm
30.76in
Stabilizers
Approximate Dimension
Figure 8.b.c Cool Wall Advantage vent dimensions
MATERIAL
FRACTIONAL
FINISH
DATE
X.XX
X.XXX
WEIGHT (lbs)
26/05/2017
ANGULAR:
BEND ALLOW.
UNLESS OTHERWISE SPECIFIED
1/19/2017
3" Min. from
K-FACTOR
SIZE
DWG. NO.
SIZE
DWG. NO.
REV.
TV Kit Framing
TV Kit Framing
ceiling
1:32
1:32
1 OF 2
SCALE:
SCALE:
SHEET:
SHEET:
4" Max
Depth
Figure 8.b.d Cool Wall Advantage TV recess dimensions
236mm
9.28in
160mm
6.3in
DL63 Heat Distrib
DIM ARE IN INCHES
NAME
DATE
1/32
DRAWN
CF
26/05/2017
.015
.005
CHECKED
CF
1/19/2017
SIZE
DWG. NO.
1
THIRD ANGLE PROJECTION
A
ALL BENDS ARE 90
SCALE:
REV.
1 OF 2
15
DL63-Heat distri
1:16
S