Commissioning
Parameter
Parameter 0-01 Language
Parameter 0-20 Display Line 1.1 Small
Parameter 0-21 Display Line 1.2 Small
Parameter 0-22 Display Line 1.3 Small
Parameter 0-23 Display Line 2 Large
Parameter 0-24 Display Line 3 Large
Parameter 15-51 Frequency Converter Serial
Number
Table 4.8 Q1 My Personal Menu Settings, FC 302
4.3.3.3 Q2 Quick Setup
The parameters in Q2 Quick Setup are the basic parameters
that are always necessary for set-up. This menu provides
the most efficient set-up for most applications. Perform the
unit set-up in the order listed. See chapter 4.4.1 Entering
System Information for the set-up steps.
4.3.3.4 Q5 Changes Made
Select Q5 Changes Made to get information about:
The 10 most recent changes.
Changes made from default setting.
4.3.3.5 Q6 Loggings
Use Q6 Loggings for fault finding.
To get information about the display line readout, select
Loggings. The information is shown as graphs. Only display
parameters selected in parameter 0-20 Display Line 1.1
Small and parameter 0-24 Display Line 3 Large can be
viewed. It is possible to store up to 120 samples in the
memory for later reference.
Q6 Loggings
Parameter 0-20 Display Line 1.1 Small
Parameter 0-21 Display Line 1.2 Small
Parameter 0-22 Display Line 1.3 Small
Parameter 0-23 Display Line 2 Large
Parameter 0-24 Display Line 3 Large
Table 4.9 Loggings Parameter Examples
MG37L202
User Guide
4.3.3.6 Main Menu Mode
Default setting
English
Speed [RPM]
The LCP provides access to the Main Menu mode. Select
the Main Menu mode by pressing the [Main Menu] key.
Motor Current
The resulting readout appears on the LCP display.
Power [kW]
Frequency
18.4%
Reference %
Main Menu
Keypad Set-Up
Parameter Data Set
Parameter Data Check
Drive Information
07 Motor Setup
Illustration 4.3 Main Menu View
Lines 2 through 5 on the display show a list of parameter
groups that can be selected via the
All parameters can be changed in the Main Menu. Option
cards added to the unit enable extra parameters associated
with the option device.

4.4 Programming the Drive System

For detailed information on the key functions on the local
control panel (LCP), see chapter 4.3 Local Control Panel
(LCP). For information on parameter settings, see
chapter 4.7 Parameter Settings.
Parameter overview
Parameter settings control the operation of the drive
system, and are accessed via the LCP. These settings are
assigned a default value at the factory, but customers can
configure them for their unique application. Each
parameter has a name and number that remain the same
Speed [RPM]
regardless of the programming mode.
Motor current
Power [kW]
In the Main Menu mode, the parameters are divided into
Frequency
groups. The first digit of the parameter number (from the
Reference %
left) indicates the parameter group number. The parameter
group is then broken down into sub-groups, if necessary.
For example:
0-** Operation/Display
0-0* Basic Settings
Parameter 0-01 Language
Parameter 0-02 Motor Speed Unit
Parameter 0-03 Regional Settings
Table 4.10 Example of Parameter Group Hierarchy
Danfoss A/S © 08/2017 All rights reserved.
5.22A
1(1)
and
keys.
Parameter group
Parameter sub-group
Parameter
Parameter
Parameter
17