Mains Supply 3X525-690 V Ac - Danfoss VLT AQUA Drive FC 202 Operating Instructions Manual

0.25-90 kw
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Specifications

8.1.6 Mains Supply 3x525-690 V AC

Type Designation
Typical Shaft output (kW)
IP20/ Chassis
Output current
Continuous (3x525-550 V) [A]
Intermittent (3x525-550 V) [A]
Continuous (3x551-690 V) [A]
Intermittent (3x551-690 V) [A]
Continuous KVA 525 V AC
Continuous KVA 690 V AC
Max. input current
Continuous (3x525-550 V) [A]
Intermittent (3x525-550 V) [A]
Continuous (3x551-690 V) [A]
Intermittent (3x551-690 V) [A]
Additional specifications
5)
Max. cable cross-section
for mains, motor, brake and
2
load sharing [mm
] ([AWG])
5)
Max. Cable cross-section
for disconnect
[mm
2
] ([AWG])
Estimated power loss at rated max. load (W)
3)
Efficiency
Table 8.9 A3 Enclosure, Mains Supply 3x525-690 V AC IP20/Protected Chassis, P1K1-P7K5
Type Designation
Typical Shaft output at 550 V [kW]
Typical Shaft output at 690 V [kW]
IP20/Chassis
IP21/Type 1, IP55/Type 12
Output current
Continuous (3x525-550 V) [A]
Intermittent (60 s overload) (3x525-550 V) [A]
Continuous (3x551-690 V) [A]
Intermittent (60 s overload) (3x551-690 V) [A]
continuous KVA (at 550 V) [KVA]
continuous KVA (at 690 V AC) [KVA]
Max. input current
Continuous (at 550 V) (A)
Intermittent (60 s overload) (at 550 V) (A)
Continuous (at 690 V) (A)
Intermittent (60 s overload) (at 690 V) (A)
Additional specifications
5)
Max. cable cross-section
for mains/motor, load
2
share and brake [mm
] ([AWG])
Max cable cross-section
54)
for mains disconnect
[mm
2
] ([AWG])
Estimated power loss at rated max. load (W)
3)
Efficiency
Table 8.10 B2/B4 Enclosure, Mains Supply 3x525-690 V AC IP20/IP21/IP55 - Chassis/NEMA 1/NEMA 12, P11K-P22K
®
VLT
AQUA Drive FC 202 Operating Instructions
P1K1
P1K5
1.1
1.5
A3
A3
2.1
2.7
3.4
4.3
1.6
2.2
2.6
3.5
1.9
2.5
1.9
2.6
1.9
2.4
3.0
3.9
1.4
2.0
2.3
3.2
4)
44
60
0.96
0.96
P11K
11
15
B4
B2
19.0
20.9
18.0
19.8
18.1
21.5
19.5
21.5
19.5
21.5
4)
220
0.98
MG20MA02 - Rev. 2013-10-29
P2K2
P3K0
P4K0
2.2
3.0
4.0
A3
A3
A3
3.9
4.9
6.1
6.2
7.8
9.8
3.2
4.5
5.5
5.1
7.2
8.8
3.5
4.5
5.5
3.8
5.4
6.6
3.5
4.4
5.5
5.6
7.0
8.8
2.9
4.0
4.9
4.6
6.5
7.9
4, 4, 4 (12, 12, 12) (min. 0.2 (24)
6, 4, 4 (10, 12, 12)
88
120
160
0.96
0.96
0.96
P15K
P18K
15
18.5
18.5
22
B4
B4
B2
B2
23.0
28.0
25.3
30.8
22.0
27.0
24.2
29.7
21.9
26.7
26.3
32.3
24.0
29.0
26.4
31.9
24.0
29.0
26.4
31.9
35, 25, 25 (2, 4, 4)
16,10,10 (6, 8, 8)
300
370
0.98
0.98
P5K5
P7K5
5.5
7.5
A3
A3
9.0
11.0
14.4
17.6
7.5
10.0
12.0
16.0
8.2
10.0
9.0
12.0
8.1
9.9
12.9
15.8
6.7
9.0
10.8
14.4
8
220
300
0.96
0.96
P22K
22
30
B4
B2
36.0
39.6
34.0
37.4
34.3
40.6
36.0
39.6
36.0
39.6
440
0.98
49
8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AQUA Drive FC 202 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents