SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
17. Fuel Filter (Gasoline) - GM
Lube Point(s) - Replaceable Element
Interval - Every 6 months or 300 hours of operation
18. Air Filter
Lube Point(s) - Replaceable Element
Interval - Every 6 months or 300 hours of operation or as indi-
cated by the condition indicator
6-28
19. Electronic Pressure Regulator (LP only)
Interval - 3 Months or 150 hours of operation
Comments - Drain oil build up. Refer to Section 6.5, DRAIN-
ING OIL BUILD UP FROM THE PROPANE REGULATOR (Prior to
S/N 0300134626)
– JLG Lift –