SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
10. Oil Change w/Filter - Isuzu
Lube Point(s) - Fill Cap/Spin-on Element
Capacity - 8.5 qt. (8.0L) engine; 5.3 qt. (5.L) cooler
Lube - EO
Interval - Change oil after first 50 and every 200 hrs. there
after. Change oil filter after 50hrs. and every 400 hrs. there
after.
Comments - Check level daily/Change in accordance with
engine manual.
11. Oil Change w/Filter - Caterpillar
Lube Point(s) - Fill Cap/Spin-on Element
Capacity - 10.6 Quarts
Lube - EO
Interval - 3 Months or 150 hours of operation
Comments - Check level daily/Change in accordance with
engine manual.
6-26
12. Oil Change w/Filter - GM
Lube Point(s) - Fill Cap/Spin-on Element
(JLG P/N 7027965)
Capacity - 4.5 qt. (4.25 L) w/filter
Lube - EO
Interval - 3 Months or 150 hours of operation
Comments - Check level daily/Change in accordance with
engine manual.