SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
6. Hydraulic Tank
Lube Point(s) - Fill Cap
Capacity - 40 gallons (151 L) Tank; 77 gallons (291.4 L) Sys-
tem
Lube - HO
Interval - Check Level daily; Change every 2 years or 1200
hours of operation.
6-24
7. Suction Strainers
Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation, remove
and clean at time of hydraulic oil change.
– JLG Lift –