8 Maintenance

8
Maintenance
Replacing Filter Mats
Power off the unit before replacing or removing the filter mats.
Replacing or removing filter mats while the unit is powered on may result in electric shock or malfunction of the unit.
Base of the Unit
Perform as follows to remove the filter mats from the base of the unit:
1. Remove the screws that hold the aire intake grill.
2. Remove the front panel from the base and remove the filter mat from inside the panel for replacement.
3. Refit the filter mat inside the panel and replace the panel.
4. Torque the screws to 1.3 Nm.
Figure 3
8-M4x12
Hood of the Unit
Perform as follows to remove the filter mats from the hood of the unit:
1. Remove the screws that hold the hood roof in place.
2. Remove the hood roof from the enclosure and remove the filter mat from inside the hood for replacement.
3. Refit the filter mat inside the hood and replace the hood roof.
4. Torque the screws to 4.5 Nm.
Figure 4
EN 38
Filter
8-M4x12