Monitor
U1-01
Frequency Reference (Hz)
U1-02
Output Frequency (Hz)
U1-03
Output Current (A)
U1-05
Motor Speed (Hz)
U1-06
Output Voltage Reference (Vac)
U1-07
DC Bus Voltage (Vdc)
U1-08
Output Power (kW)
U1-09
Torque Reference (% of motor rated torque)
Displays the input terminal status.
U1 - 10=
0 0 0 0 0 0 0 0
U1-10
Displays the output terminal status.
U1 - 11=
0 0 0 0 0 0 0 0
U1-11
Verifies the drive operation status.
U1 - 12=
0 0 0 0 0 0 0 0
U1-12
U1-13
Terminal A1 Input Level
U1-14
Terminal A2 Input Level
U1-15
Terminal A3 Input Level
U1-16
Output Frequency after Soft Starter
U1-18
oPE Fault Parameter
U1-24
Input Pulse Monitor
U2-01
Current Fault
U2-02
Previous Fault
U2-03
Frequency Reference at Previous Fault
U2-04
Output Frequency at Previous Fault
YASKAWA Europe TOEP C710616 88A - AC Drive A1000 IP23/54 Floor Standing - Quick Start Guide
Description
1
Digital input 1
(terminal S1 enabled)
1
Digital input 2
(terminal S2 enabled)
1
Digital input 3
(terminal S3 enabled)
1
Digital input 4
(terminal S4 enabled)
1
Digital input 5
(terminal S5 enabled)
1
Digital input 6
(terminal S6 enabled)
1
Digital input 7
(terminal S7 enabled)
1
Digital input 8
(terminal S8 enabled)
1
Multi-Function
Digital Output
(terminal M1-M2)
1
Multi-Function
Digital Output
(terminal M3-M4)
1
Multi-Function
Digital Output
(terminal M5-M6)
Not Used
1
Fault Relay
(terminal MA-MC closed
MA-MC open)
1
During run
1
During zero-speed
1
During REV
1
During fault reset
signal input
1
During speed agree
1
Drive ready
1
During alarm
detection
1
During fault detection
Fault Trace
Monitor
U2-05
Output Current at Previous Fault
U2-06
Motor Speed at Previous Fault
U2-07
Output Voltage at Previous Fault
U2-08
DC Bus Voltage at Previous Fault
U2-09
Output Power at Previous Fault
U2-10
Torque Reference at Previous Fault
U2-11
Input Terminal Status at Previous Fault
U2-12
Output Terminal Status at Previous Fault
U2-13
Drive Operation Status at Previous Fault
U2-14
Cumulative Operation Time at Previous Fault
U2-15
Soft Starter Speed Reference at Previous Fault
U2-16
Motor q-Axis Current at Previous Fault
U2-17
Motor d-Axis Current at Previous Fault
U2-20
Heatsink Temperature at Previous Fault
Fault History
U3-01 to
First to 4th Most Recent Fault
U3-04
U3-05 to
5th to 10th Most Recent Fault
U3-10
U3-11 to
Cumulative Operation Time at 1st to 4th Most Recent
U3-14
Fault
U3-15 to
Cumulative Operation Time at 5th to 10th Most Recent
U3-20
Fault
NOTE: The following faults are not recorded in the error log.
CPF00 to 03, Uv1, and Uv2
DI/DO Sel.
Digital Input Function Selections
3
Multi-step speed reference 1
4
Multi-step speed reference 2
5
Multi-step speed reference 3
Jog reference selection (higher priority than multi-step
6
speed reference)
7
Accel/decel time selection 1
F
Through mode (Set when a terminal is not used)
14
Fault reset (Reset when turned ON)
External fault; Input mode: N.O. contact / N.C. contact,
20 to 2F
Detection mode: Normal/during operation
Digital Output Function Selections
During Run (ON: run command is ON or voltage is being
0
output)
1
Zero Speed
2
Speed Agree 1
6
Drive Ready
E
Fault
F
Through mode
10
Minor fault (Alarm) (ON: Alarm displayed)
6 Parameter Table
Description
Description
EN 33