Replacing Batteries; Related Service - Fujitsu ETERNUS DX500 S4 Operation Manual

Hybrid storage systems
Hide thumbs Also See for ETERNUS DX500 S4:
Table of Contents

Advertisement

6.
Maintenance
Maintenance Service

Replacing Batteries

The batteries of the ETERNUS DX are expendable components that need to be replaced periodically.
Batteries can be replaced during regular maintenance free of charge. For customers without a maintenance con-
tract, replacement requests (payment required) must be made.
Replacement Cycle for a Battery
If a battery is used at an average temperature of 25 °C, the battery can be used for the entire maintenance sup-
port period (five years). The replacement cycle for a battery varies according to the customer's environment and
usage.
Checking the Time to Replace the Battery
The time to replace the battery can be checked by using the following options.
If the time to replace the battery is near, contact your maintenance engineer.
Check the time to replace the battery by using ETERNUS Web GUI or ETERNUS CLI.
If the time to replace the battery is near, a notification is sent via an e-mail or an SNMP trap message.
A notification is sent six months before the expiration date.
-
-
A notification is sent everyday for a week before the expiration date.

Related Service

Remote Support
If a possible error that may occur is detected or an error occurs when remote support service is used, the con-
tents of events are automatically sent to the remote support center and notified to the user.
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Operation Guide (Basic)
Do
The replacement cycle for a battery is shortened if the battery is used at high tempera-
tures or the battery charges and discharges frequently.
If the time to replace the battery is near, contact your maintenance engineer to re-
place the battery. If the battery is still used even after the replacement time has
passed, the performance of the ETERNUS DX degrades because the operational state
of the cache is changed to Write Through mode.
69
Copyright 2018 FUJITSU LIMITED
P3AM-7742-12ENZ0