8.1

Programming example for reading the inverter status

The following program turns ON Y00 of the output unit when station 1 inverter is running.
SB49
SW0B0.0
0
M0
X1002
3
Inverter running (RX02)
6
Remote input
One
RX3F to RX00
station

X101F
b15
b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
0
0
b31 b30 b29 b28 b27 b26 b25 b24 b23 b22 b21 b20 b19 b18 b17 b16
0
0
Inverter status
b0 : During forward rotation
b0 : During forward rotation
b2 : Running (RUN) ∗1
b3 : Up to frequency (SU) ∗1
b4 : Overload alarm (OL) ∗1
b5 : Instantaneous power failure (IPF) ∗1
b6 : Frequency detection (FU) ∗1
b7 : Fault (ABC1) ∗1
b8 :
b16 :
b17 :
b18 :
These signals are initial values. You can change output signals using Pr.190 to Pr.196, Pr.313 to
Pr.315 (output terminal function selection).
Check the data link status of the station 1
M0
Turn on the output unit (Y00)
Y30
END
0
0
0
0
0
0
0
0
[Inverter status]
0
0
0
0
0
0
0
0
(ABC2) ∗1
(DO0) ∗1
(DO1) ∗1
(DO2) ∗1
PROGRAMMING EXAMPLES
X1000
0
0
0
0
0
0
0
0
0
0
0
0
[Inverter status]
8
75