Mitsubishi Electric FR-A8NCE Instruction Manual page 44

Inverter plug-in option, cc-link ie field network communication function
Table of Contents

Advertisement

• Output from the master station
(1) The device of the CPU module turns ON.
(2) The device status data of the CPU module are stored in the link devices (RY and RWw) of the master station by link
refresh.
(3) The status data of the link devices (RY and RWw) of the master station are stored in the link devices (RY and RWw) of
each slave station by link scan.
(4) The inverter starts according to the link device (RY and RWw) conditions (input signals such as STF and STR) of the slave
station.
• Input from the slave station
(5) Inverter conditions (output signals such as RUN and SU, monitoring) are stored in the link devices (RX and RWr) of the
slave station.
(6) The status data of the link devices (RX and RWr) of the slave station are stored in the link devices (RX and RWr) of the
master station by link scan.
(7) The status data of the link devices (RX and RWr) of the master station are stored in the devices of the CPU module by link
refresh.
NOTE
• Refer to the MELSEC iQ-R, MELSEC-Q, or MELSEC-L CC-Link IE Field Network Master/Local Module User's Manual
for the detailed assignment methods for the link devices and link refresh.
FUNCTION OVERVIEW
5
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents