Inverter Reset - Mitsubishi Electric FR-A8NCE Instruction Manual

Inverter plug-in option, cc-link ie field network communication function
Table of Contents

Advertisement

4.4

Inverter reset

 Operation conditions of inverter reset
Which resetting method is allowed or not allowed in each operation mode is described below.
Inverter reset (Refer to
Reset from the
Error reset at inverter fault
network
(Refer to
Turn on the RES signal (terminal RES) of the inverter
Switch off inverter power
Inverter reset
Reset from the PU/
DU
Reset at inverter fault

Inverter reset can be made any time.

Reset can be made only when the protective function of the inverter is activated.
NOTE
• When a communication line error has occurred, reset cannot be made from the network.
• The inverter is set to the External operation mode if it has been reset in Network operation mode in the initial status.
To resume the network operation, the inverter must be switched to the Network operation mode again.
Set a value other than "0" in Pr.340 to start in the Network operation mode. (Refer to
• Communication continues during inverter reset. The inverter cannot be controlled for about 1 s after release of a reset
command.
• Refer to
page 84
34
INVERTER SETTING
Resetting method
page
65.)

page
55.)

for an inverter reset program example.
Network
operation
Allowed
Pr.349 = 0
Allowed
Pr.349 = 1
Allowed
Allowed
Allowed
Allowed
Operation mode
External
PU operation
operation
Disallowed
Disallowed
Allowed
Allowed
Disallowed
Disallowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
page
25.)